陶瓷轴承与初次全髋关节置换翻修率显著降低相关:英格兰、威尔士、北爱尔兰和马恩岛国家关节登记分析
基于国家关节登记系统2002至2016年456,457例非骨水泥髋臼初次全髋关节置换(THA),比较陶瓷对陶瓷(CoC)、陶瓷对聚乙烯(CoP)与金属对聚乙烯(MoP)轴承的翻修结局。多变量竞争风险模型显示,CoC和CoP相比MoP的假体周围感染(PJI)翻修风险显著降低,无菌性及全因翻修风险也显著降低,且陶瓷的保护效应主要在植入2年后显现。结论支持在THA中使用陶瓷轴承。
要点
- 陶瓷轴承(CoC和CoP)与MoP相比,PJI翻修风险显著降低。
- 陶瓷轴承的无菌性翻修和全因翻修风险也显著低于MoP。
- 陶瓷的保护效应主要在植入2年后显现。
核心结论
- 使用陶瓷作为轴承组成部分与全因翻修、感染翻修及无菌性翻修率降低相关,支持在THA中使用陶瓷轴承。
研究设计与样本
- 回顾性分析国家关节登记系统(英格兰、威尔士、北爱尔兰和马恩岛)2002至2016年接受非骨水泥髋臼初次THA的成年患者,采用竞争风险回归模型分析各翻修结局的预测因素,并调整年龄、性别、ASA分级、BMI、手术指征、术中并发症和植入物数据。
主要发现
- 共纳入456,457例THA,其中MoP 228,786例、CoC 128,403例、CoP 99,268例。
- 多变量模型显示,相比MoP,CoC的PJI翻修风险比为0.748(P < .001),CoP为0.775(P < .001)。
- 无菌性翻修和全因翻修风险也显著降低。
- 陶瓷轴承的显著保护效应主要在植入2年后显现:2年后无菌性翻修CoC降低18.1%、CoP降低24.8%(P < .001)。
- 2年后全因翻修率CoC降低21.6%、CoP降低27.1%(P < .001)。
临床怎么用
- 在初次非骨水泥THA中,可考虑选用陶瓷轴承(CoC或CoP)以降低PJI、无菌性及全因翻修风险。
- 陶瓷轴承的翻修风险降低主要在植入2年后显现,临床决策时可结合患者预期寿命和远期获益评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. METHODS: Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data. RESULTS: In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001) CONCLUSION: This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.
引用
- Holleyman RJ, Critchley RJ, Mason JM, et al. Ceramic Bearings Are Associated With a Significantly Reduced Revision Rate in Primary Hip Arthroplasty: An Analysis From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. J Arthroplasty. 2021. PMID: 34238620. doi:10.1016/j.arth.2021.05.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。