文献速递关节外科

荷兰关节登记:内侧单髁膝关节置换翻修风险与固定及轴承类型的关系

Risk of revision for medial unicompartmental knee arthroplasty according to fixation and bearing type : short- to mid-term results from the Dutch Arthroplasty Register.
PubMed 文献 · Bone Joint J · 2021-01-01

基于荷兰关节登记2007至2018年21,610例内侧单髁膝关节置换,比较非骨水泥活动轴承与骨水泥活动/固定轴承的生存率。年手术量超过100例的医院中,骨水泥活动轴承翻修风险高于非骨水泥活动轴承(HR 1.78,95%CI 1.34–2.35);骨水泥固定轴承与非骨水泥活动轴承翻修风险相当,不依赖医院年手术量。

要点

  • 年手术量>100例的医院中,骨水泥活动轴承翻修风险高于非骨水泥活动轴承(HR 1.78,95%CI 1.34–2.35)。
  • 骨水泥固定轴承与非骨水泥活动轴承的调整翻修风险相当,不依赖医院年手术量。
  • 非骨水泥活动轴承翻修中假体周围骨折占10.0%、不稳占23.6%、轴承更换占40%。

核心结论

  • 在年手术量超过100例的医院中,非骨水泥活动轴承较骨水泥活动轴承翻修生存更优。
  • 骨水泥固定轴承与非骨水泥活动轴承的翻修风险相当,不依赖医院年手术量。

研究设计与样本

  • 回顾性队列研究,数据来自荷兰关节登记,纳入2007至2018年21,610例内侧单髁膝关节置换。
  • 采用多变量Cox回归比较非骨水泥活动轴承与骨水泥活动及固定轴承,并调整患者与手术因素及其交互作用。

主要发现

  • 年手术量<100例的医院中,骨水泥活动轴承与非骨水泥活动轴承的调整翻修风险相当。
  • 年手术量>100例的医院中,骨水泥活动轴承较非骨水泥活动轴承调整翻修风险更高(HR 1.78,95%CI 1.34–2.35)。
  • 骨水泥固定轴承与非骨水泥活动轴承的调整翻修风险相当,不依赖医院年手术量。
  • 翻修原因中,胫骨部件松动占比:非骨水泥活动轴承12.3%、骨水泥活动轴承20.3%、非骨水泥固定轴承41.5%。
  • 不稳占比:非骨水泥活动轴承23.6%、骨水泥活动轴承14.5%、非骨水泥固定轴承11.7%;假体周围骨折占比分别为10.0%、2.8%、3.5%。

关键数值与推荐

  • 轴承更换占翻修的比例:非骨水泥活动轴承40%、骨水泥活动轴承24.3%、骨水泥固定轴承5.3%。

临床怎么用

  • 年手术量超过100例的医院选择非骨水泥活动轴承可能获得更优生存,但需关注不稳、假体周围骨折和轴承更换风险。
  • 骨水泥固定轴承可作为非骨水泥活动轴承的替代选择,其翻修风险不依赖医院年手术量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. METHODS: A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed. RESULTS: In hospitals performing less than 100 cases per year, cemented mobile bearings reported comparable adjusted risks of revision as uncemented mobile bearings. However, in hospitals performing more than 100 cases per year, the adjusted risk of revision was higher for cemented mobile bearings compared to uncemented mobile bearings (hazard ratio 1.78 (95% confidence interval 1.34 to 2.35)). The adjusted risk of revision between cemented fixed bearing and uncemented mobile bearing was comparable, independent of annual hospital volume. In addition, 12.3% of uncemented mobile bearing, 20.3% of cemented mobile bearing, and 41.5% of uncemented fixed bearing revisions were for tibial component loosening. The figures for instability were 23.6%, 14.5% and 11.7%, respectively, and for periprosthetic fractures were 10.0%, 2.8%, and 3.5%. Bearing exchange was the type of revision in 40% of uncemented mobile bearing, 24.3% of cemented mobile bearing, and 5.3% cemented fixed bearing revisions. CONCLUSION: The findings of this study demonstrated improved survival with use of uncemented compared to cemented mobile bearings in medial UKA, only in those hospitals performing more than 100 cases per year. Cemented fixed bearings reported comparable survival results as uncemented mobile bearings, regardless of the annual hospital volume. The high rates of instability, periprosthetic fractures, and bearing exchange in uncemented mobile bearings emphasize the need for further research. Cite this article: Bone Joint J 2021;103-B(7):1261-1269.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Burger JA, Zuiderbaan HA, Sierevelt IN, et al. Risk of revision for medial unicompartmental knee arthroplasty according to fixation and bearing type : short- to mid-term results from the Dutch Arthroplasty Register. Bone Joint J. 2021. PMID: 34192933. doi:10.1302/0301-620X.103B7.BJJ-2020-1224.R3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。