全涂层羟基磷灰石柄显著透亮线发生的危险因素
本研究对288例未翻修的Corail柄全髋关节置换患者进行10年放射学与牛津髋关节评分随访,提出将透亮线分为无、良性和显著三类。多因素回归显示,非交联聚乙烯、无领设计、柄尺寸偏小和男性是显著透亮线的危险因素,年龄增加则降低风险;显著透亮线患者疼痛评分更高,但牛津髋关节评分总体无显著差异。
要点
- 非交联聚乙烯、无领柄、尺寸偏小和男性是显著透亮线的危险因素。
- 年龄增加与显著透亮线风险降低相关。
- 显著透亮线患者疼痛评分更高,但总体牛津髋关节评分无显著差异。
核心结论
- 本研究提出的显著透亮线定义与非交联聚乙烯、无领设计、尺寸偏小及更高疼痛评分显著相关。
研究设计与样本
- 对288例未翻修的Corail柄全髋关节置换患者进行10年放射学与牛津髋关节评分随访的队列研究。
主要发现
- 多因素回归分析中,除性别外,良性透亮线与无透亮线组间无显著差异,故将两组合并为非显著透亮线组与显著透亮线组比较。
临床怎么用
- 对于使用非交联聚乙烯、无领柄、尺寸偏小或男性患者,应警惕显著透亮线发生风险。
- 术后随访中关注透亮线进展及疼痛症状,尤其在高风险患者中。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The risk factors for and clinical impact of radiolucent lines (RLLs) in cementless total hip arthroplasty remain contentious. The aim of this work was to describe a method of classification that has clinical significance and to identify risk factors. METHODS: A cohort of 288 subjects with unrevised Corail stems (DePuy Synthes, Warsaw, IN) were reviewed with radiographs and Oxford Hip Scores at 10 years. Based on clinical experience, three groups were defined; those with no RLLs (NoRLLs), those considered to have benign RLLs (BenRLLs), and those considered to have significant RLLs (SigRLLs). SigRLLs were then compared to BenRLLs and NoRLLs to determine the validity of this classification. RESULTS: One hundred and nine (37.8%) had NoRLLs, 111 (38.5%) had BenRLLs, and 68 (23.6%) had SigRLLs. No significant difference apart from gender was noted between the occurrence of BenRLLs and NoRLLs after multinomial regression analysis, consequently the NoRLLs and BenRLLs groups were combined (NoSigRLLs) and compared to SigRLLs. Non-cross-linked polyethylene (odds ratio = 4.6, P < .001), collarless stem design (odds ratio = 9.4, P < .001), undersizing (odds ratio = 1.2, P = .028), and male sex (odds ratio = 2.1, P = .008) were risk factors for SigRLLs. Regression analysis also revealed that increasing age at operation decreased the likelihood of SigRLLs (P < .001). Patients with SigRLLs had significantly higher pain scores (P = .005) although overall Oxford Hip Scores were not significantly different (P = .364). CONCLUSION: The definition of SigRLLs proposed in this study was significantly associated with that of non-cross-linked polyethylene, absence of a collar, undersizing, and higher pain scores.
引用
- Karayiannis PN, Cassidy RS, Isaac G, et al. Risk Factors for Significant Radiolucent Line Development in a Fully Coated Hydroxyapatite Stem. J Arthroplasty. 2021. PMID: 34303582. doi:10.1016/j.arth.2021.07.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。