文献速递关节外科

髋关节融合转全髋关节置换术的并发症、功能结果与长期生存综述

Review of complications, functional outcome, and long-term survival following conversion of hip fusion to total hip arthroplasty.
PubMed 文献 · Bone Joint J · 2021-01-01

本研究回顾性分析38例患者39例髋关节融合转全髋关节置换术,采用统一技术和非骨水泥假体,平均随访12.2年。结果显示Harris髋关节评分显著提高,并发症率较低,10年假体生存率97.1%,15年88.2%(无菌性松动为终点)。

要点

  • 髋关节融合转全髋关节置换术可显著改善功能(HHS从34.2升至75,p<0.001)。
  • 术后68.4%患者仍需使用行走辅助工具,术前应告知患者。
  • 异位骨化发生率为40%,其中7.7%需手术切除。

核心结论

  • 采用优化且统一的手术技术及非骨水泥假体,髋关节融合转全髋关节置换术可获得显著功能改善、低并发症率、长期假体生存率及高患者满意度。

研究设计与样本

  • 回顾性研究,共纳入38例患者39例髋关节融合转全髋关节置换术,由单一外科医生采用统一手术技术和非骨水泥假体完成。

主要发现

  • 平均随访12.2年(2至24年),Harris髋关节评分从平均34.2(20.8至60.5)提高至75(53.6至94.0;p<0.001)。
  • 术后平均活动度:屈曲77°(50°至95°),外展30°(10°至40°),内收20°(5°至25°),内旋18°(2°至30°),外旋17°(5°至30°)。
  • 下肢不等长从平均-3.36 cm(0至8)改善至术后平均-1.14 cm(0至4;p<0.001)。
  • 术后26例患者(68.4%)需要使用行走辅助工具。
  • 并发症包括1例(2.5%)脱位、2例(5.1%)部分坐骨神经损伤、1例(2.5%)假体周围深部感染、2例(5.1%)髋臼组件无菌性松动、2例(5.1%)假体周围骨折、10例(40%)异位骨化,其中3例(7.7%)功能受限需切除。

关键数值与推荐

  • 以无菌性松动为终点的假体生存率:10年97.1%(95%CI 91.4%至100%),15年88.2%(95%CI 70.96%至100%)。
  • 以全因失败为终点的假体生存率:10年81.7%(95%CI 70.9%至98.0%),15年74.2%(95%CI 55.6%至92.8)。

临床怎么用

  • 对于髋关节融合患者,采用统一技术和非骨水泥假体行转全髋关节置换术可显著改善功能和生活质量。
  • 术前应与患者讨论术后可能需要行走辅助工具(68.4%患者需要)。
  • 术后需警惕异位骨化(40%发生率),其中部分需手术切除。

局限性

  • 回顾性研究设计,样本量较小(39例髋),由单一外科医生完成,结果可能受术者经验影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. METHODS: A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. RESULTS: At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. CONCLUSION: The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129-134.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Ayekoloye CI, Abu Qa'oud M, Radi M, et al. Review of complications, functional outcome, and long-term survival following conversion of hip fusion to total hip arthroplasty. Bone Joint J. 2021. PMID: 34192904. doi:10.1302/0301-620X.103B7.BJJ-2020-2382.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。