文献速递关节外科脊柱外科

脊柱骨盆活动度影响髋臼假体前倾角在侧位片上的测量准确性

Spinopelvic mobility affects accuracy of acetabular anteversion measurements on cross-table lateral radiographs.
PubMed 文献 · Bone Joint J · 2021-01-01

该回顾性研究纳入47例全髋关节置换术后患者,比较交叉侧位X线片与CT三维重建测量的髋臼假体前倾角,发现脊柱骨盆活动度差异可解释侧位片测量误差,腰椎僵硬和骨盆代偿性活动增加的患者侧位片测量准确性较低,可靠评估可能需要CT扫描。

要点

  • 交叉侧位片与CT测量髋臼前倾角的误差≥10°见于11例患者。
  • 腰椎僵硬和骨盆代偿性活动增加与侧位片测量误差相关。
  • 对腰椎僵硬患者,可靠评估髋臼前倾角可能需要CT扫描。

核心结论

  • 脊柱骨盆活动度差异可解释交叉侧位X线片测量髋臼前倾角的变异性。
  • 腰椎僵硬且骨盆代偿性活动增加的患者,交叉侧位片测量准确性较低。
  • 对这类患者,可靠分析髋臼假体前倾角可能需要CT扫描等高级影像。

研究设计与样本

  • 回顾性纳入47例全髋关节置换术后患者,男27例、女20例,平均年龄62.9岁(SD 6.95)。
  • 基于交叉侧位片与CT测量误差≥10°(n=11)或<10°(n=36)分为两组。
  • 比较两组脊柱骨盆活动度参数,并采用Pearson系数评估误差与活动度参数的相关性。

主要发现

  • 误差>10°组(10°至14°)腰椎屈曲度更低:38.9°(SD 11.6°)vs 47.4°(SD 13.1°),p=0.030。
  • 误差>10°组骨盆入射角-腰椎前凸匹配差异为5.9°(SD 18.8°)vs -1.7°(SD 9.8°),p=0.042。
  • 误差>10°组坐位骨盆后倾更大:骨盆倾斜-9.7°(SD 14.1°)vs -2.2°(SD 13.2°),p=0.050。
  • 误差>10°组仰卧位与坐位骨盆倾斜变化更大:12.6°(SD 12.1°)vs 4.7°(SD 12.5°),p=0.036。
  • 交叉侧位片测量误差与交叉侧位片前倾角(r=0.5,p=0.001)、坐位腰椎前凸(r=0.4,p=0.009)等呈正相关。

关键数值与推荐

  • 交叉侧位片与CT测量误差≥10°定义为误差组(n=11),<10°为对照组(n=36)。
  • 腰椎屈曲度、骨盆入射角-腰椎前凸匹配、坐位骨盆倾斜及仰卧位-坐位骨盆倾斜变化在两组间差异有统计学意义。

临床怎么用

  • 交叉侧位片测量髋臼前倾角可能因脊柱骨盆活动度差异而不准确。
  • 对腰椎僵硬、骨盆代偿性活动增加的患者,应考虑CT扫描以可靠评估髋臼假体前倾角。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy. METHODS: THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples t-tests. Correlation between error and mobility parameters were assessed with Pearson's coefficient. RESULTS: Patients with CTL error > 10° (10° to 14°) had stiffer lumbar spines with less mean lumbar flexion (38.9°(SD 11.6°) vs 47.4° (SD 13.1°); p = 0.030), different sagittal balance measured by pelvic incidence-lumbar lordosis mismatch (5.9° (SD 18.8°) vs -1.7° (SD 9.8°); p = 0.042), more pelvic extension when seated (pelvic tilt -9.7° (SD 14.1°) vs -2.2° (SD 13.2°); p = 0.050), and greater change in pelvic tilt between supine and seated positions (12.6° (SD 12.1°) vs 4.7° (SD 12.5°); p = 0.036). The CTL measurement error showed a positive correlation with increased CTL anteversion (r = 0.5; p = 0.001), standing lordosis (r = 0.23; p = 0.050), seated lordosis (r = 0.4; p = 0.009), and pelvic tilt change between supine and step-up positions (r = 0.34; p = 0.010). CONCLUSION: Differences in spinopelvic mobility may explain the variability of acetabular anteversion measurements made on CTL radiographs. Patients with stiff spines and increased compensatory pelvic movement have less accurate measurements on CTL radiographs. Flexion of the contralateral hip is required to obtain clear CTL radiographs. In patients with lumbar stiffness, this movement may extend the pelvis and increase anteversion of the acetabulum on CTL views. Reliable analysis of acetabular component anteversion in this patient population may require advanced imaging with a CT scan. Cite this article: Bone Joint J 2021;103-B(7 Supple B):59-65.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Bracey DN, Hegde V, Shimmin AJ, et al. Spinopelvic mobility affects accuracy of acetabular anteversion measurements on cross-table lateral radiographs. Bone Joint J. 2021. PMID: 34192919. doi:10.1302/0301-620X.103B7.BJJ-2020-2284.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。