这项前瞻性研究纳入了43例年龄<65岁、BMI<35 kg/m2、UCLA活动评分>6的初次全髋关节置换术患者,使用模块化钴铬髋臼内衬、高交联聚乙烯活动轴承及非骨水泥钛股骨柄。至少5年随访时,改良Harris髋关节评分从术前54.8显著改善至93.08(p<0.001),1例因无菌性髋臼松动翻修,钴和钛离子水平轻度升高,股骨骨密度比值在Gruen 1区下降而2-7区维持。结论认为该模块化双动假体在年轻活跃患者中中期生存率优异,腐蚀和金属离子释放问题轻微。

要点

  • 模块化双动全髋关节置换术在年轻活跃患者中5年随访显示改良Harris髋关节评分显著改善。
  • 仅1例因无菌性髋臼松动接受翻修,中期生存率优异。
  • 钴和钛离子水平轻度升高,股骨骨密度仅在Gruen 1区下降。

核心结论

  • 模块化双动组件联合非骨水泥锥形股骨柄在年轻活跃初次全髋关节置换术患者中显示出优异的中期生存率,腐蚀和金属离子释放问题轻微。

研究设计与样本

  • 前瞻性研究纳入43例年龄<65岁、BMI<35 kg/m2、UCLA活动评分>6的初次全髋关节置换术患者,使用模块化钴铬髋臼内衬、高交联聚乙烯活动轴承和非骨水泥钛股骨柄。

主要发现

  • 至少5年随访时,23例(53.4%)返回临床和影像学复查,25例(58.1%)完成金属离子分析,19例(44.2%)接受双能X线吸收测定扫描,25例(58%)完成疼痛绘图问卷。
  • 改良Harris髋关节评分从术前54.8(SD 19)显著改善至术后5年93.08(SD 10.5)(p<0.001)。
  • 1例因无菌性髋臼松动接受翻修。
  • 平均钴水平从0.065 μg/l(SD 0.03)升高至0.08 μg/l(SD 0.05),平均钛水平从0.35 μg/l(SD 0.13)升高至0.78 μg/l(SD 0.29)。
  • 术后5年股骨骨密度比值在Gruen 1区降至91.9%(与术后6周基线相比),Gruen 2至7区维持。

临床怎么用

  • 对于年龄<65岁、BMI<35 kg/m2且UCLA活动评分>6的活跃患者,模块化双动全髋关节置换术可作为可行选项,中期随访显示功能改善且翻修率低。

局限性

  • 5年随访时仅部分患者完成临床复查、金属离子分析、骨密度扫描和疼痛问卷,存在随访不完整。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA. METHODS: This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m2, and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported. RESULTS: A total of 43 patients were enrolled. At minimum follow-up of five years, 23 (53.4%) returned for clinical and radiological review, 25 (58.1%) had metal ion analysis performed, 19 (44.2%) underwent dual energy x-ray absorptiometry scans, and 25 (58%) completed a pain-drawing questionnaire. The mean modified Harris Hip Scores improved significantly from 54.8 (SD 19) preoperatively to 93.08 (SD 10.5) five years postoperatively (p < 0.001). One patient was revised for aseptic acetabular loosening. The mean cobalt levels increased from 0.065 μg/l (SD 0.03) to 0.08 (SD 0.05) and the mean titanium levels increased from 0.35 (SD 0.13) to 0.78 (SD 0.29). The femoral BMD ratio decreased in Gruen Zone 1 (91.9%) at five years postoperatively compared with the baseline scores at six weeks potoperatively. The femoral BMD ratio was maintained in Gruen zones 2 to 7. CONCLUSION: The use of a modular DM component and a cementless, tapered femoral stem shows excellent mid-term survivorship with minimal concerns for corrosion and metal ion release in a cohort of young, active patients undergoing primary THA. Cite this article: Bone Joint J 2021;103-B(7 Supple B):73-77.