50岁及以下患者全髋关节置换术使用高交联聚乙烯假体至少15年随访
本研究评估50岁及以下患者使用高交联聚乙烯(HXLPE)行全髋关节置换术(THA)至少15年的临床和影像学结果。105例THA中96髋完成至少15年随访,平均随访17.3年,Harris髋关节评分从术前52.8显著改善至术后94.8,聚乙烯线性磨损率0.04 mm/年,无骨溶解或机械松动翻修。
要点
- HXLPE在年轻THA患者中长期耐磨性优异,平均线性磨损率仅0.04 mm/年。
- 至少15年随访中无因骨溶解或机械松动而翻修,仅1髋因反复不稳定翻修。
- 临床疗效显著,Harris髋关节评分从术前52.8提升至术后94.8。
核心结论
- 50岁及以下患者THA使用HXLPE假体在至少15年随访中表现优异,无明显磨损导致机械松动或需翻修。
研究设计与样本
- 87例患者(96髋)完成至少15年随访(平均17.3年,范围15-21),采用后路入路、非骨水泥固定,中位股骨头尺寸28 mm,所有髋臼均使用HXLPE。
主要发现
- 平均Harris髋关节评分从术前52.8(SD 13.5)显著改善至术后94.8(SD 7.6)。
- 1髋因反复不稳定翻修,无感染;无髋因机械松动或骨溶解翻修。
- 平均聚乙烯线性磨损0.04 mm/年,体积磨损6.22 mm³/年,不同股骨头尺寸或材料间无显著差异。
- 所有髋均无骨溶解。
关键数值与推荐
- 平均聚乙烯线性磨损率0.04 mm/年,体积磨损率6.22 mm³/年。
- Harris髋关节评分术前52.8(SD 13.5),术后94.8(SD 7.6)。
临床怎么用
- 对于50岁及以下需行THA的患者,HXLPE是可靠的承重面选择,长期磨损极低。
- 术后需随访髋臼假体周围放射透亮线以明确其预后意义。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. METHODS: Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis. RESULTS: Clinical outcomes showed significant improvement of mean Harris Hip Scores from 52.8 (SD 13.5) preoperatively to 94.8 (SD 7.6) postoperatively. One hip was revised for recurrent instability, and there were no infections. No hips were revised for mechanical loosening or osteolysis. Mean polyethylene linear wear was 0.04 mm/year and volumetric wear was 6.22 mm3/year, with no significant differences between head size or material. Osteolysis was not present in any of the hips. CONCLUSION: The use of HXLPE in THA for patients aged 50 years and younger has performed exceptionally well without evidence of significant wear causing mechanical loosening or necessitating revision. The radiolucent lines of the acetabular component must be followed to determine the prognostic significance. This investigation represents the longest clinical follow-up of a large, consecutive cohort of patients aged 50 years or younger with THA using HXLPE. This long-term analysis found negligible polyethylene wear, no incidence of aseptic loosening, and excellent clinical outcomes at and beyond 15 years of follow-up. Cite this article: Bone Joint J 2021;103-B(7 Supple B):78-83.
引用
- Roedel GG, Kildow BJ, Sveom DS, et al. Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger : minimum 15-year follow-up. Bone Joint J. 2021. PMID: 34192900. doi:10.1302/0301-620X.103B7.BJJ-2020-2443.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。