钛包裹陶瓷内衬全髋关节置换术的长期结局(15至21年结果)
研究前瞻性随访77例患者共94髋接受非骨水泥髋臼组件与陶瓷对陶瓷轴承的全髋关节置换,平均随访17.2年。髋臼设计生存率为98.9%,仅1髋因感染翻修,无陶瓷组件骨折,12.8%髋臼组件存在内衬放置不全但未导致机械问题,随访超过15年未观察骨溶解。
要点
- 钛包裹陶瓷内衬髋臼组件15年以上生存率98.9%,无因无菌性松动翻修。
- 12.8%髋臼组件出现内衬放置不全,但未导致陶瓷骨折或机械故障。
- 随访超过15年未观察到骨溶解,仅1髋出现完全性放射透亮线。
核心结论
- 该髋臼组件在超过15年随访中表现出良好的临床和影像学结果,无骨溶解,钛套陶瓷内衬不完全就位未导致机械问题。
研究设计与样本
- 前瞻性随访研究,纳入77例患者共94髋,均接受非骨水泥髋臼组件与陶瓷对陶瓷轴承,随访超过15年。
主要发现
- 平均随访17.2年时髋臼设计生存率为98.9%。
- 1髋因感染翻修,无髋臼杯松动或移位。
- 仅1髋显示完全性放射透亮线。
- 研究组无任何陶瓷组件骨折。
- 12.8%(12个)髋臼组件存在内衬放置不全。
关键数值与推荐
- 临床评估包括Harris髋关节评分和视觉模拟疼痛量表。
- 影像学分析包括整合、骨溶解和陶瓷相关机械问题(如内衬放置不全)。
- 随访超过15年未观察到骨溶解。
临床怎么用
- 对于年轻活跃患者,钛包裹陶瓷内衬设计可降低磨损并避免陶瓷骨折风险。
- 术中出现内衬不完全就位可能不需额外干预,长期未导致机械故障。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Historically, aseptic loosening and osteolysis were responsible for most of the revisions among young and more active patients. Ceramic-on-ceramic bearings reduced wear but presented mechanical issues such ceramic fracture or liner chipping during insertion. To prevent this from happening a titanium-encased alumina liner was developed. The aim of this study is to address long-term results of this specific ceramic design. METHODS: All patients received an uncemented acetabular component with ceramic-on-ceramic bearing (94 hips in 77 patients). Patients were prospectively followed over 15 years. Clinical evaluation included the Harris Hip Score and Visual Analog Scale pain scale. Radiographic analysis included integration, osteolysis, and ceramic-related mechanical issues, such as malseating of the insert. RESULTS: The studied acetabular design survivorship was 98.9% at a mean follow-up of 17.2 years. One arthroplasty was revised secondary to infection but no cup had loosened or migrated during the study. Only 1 cup showed complete radiolucent lines. There was no fracture of any ceramic component in the study group. Malseating was present in 12 acetabular components (12.8%). No osteolysis was observed with over 15 years of follow-up. CONCLUSION: In conclusion, this acetabular component demonstrates a favorable clinical and radiological outcome with over 15 years of follow-up. Osteolysis was not observed and incomplete seating of the titanium-sleeved ceramic liner did not lead to mechanical problems.
引用
- Fernández-Fernández R, Oñorbe-San Francisco F, Gil-Garay E, et al. Long-Term Outcomes of a Titanium-Encased Ceramic Liner Total Hip Arthroplasty (15 to 21Year Results). J Arthroplasty. 2021. PMID: 34238621. doi:10.1016/j.arth.2021.06.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。