文献速递关节外科创伤骨科

锥形滑配股骨柄初次全髋置换后假体周围骨折是早期翻修主因:2765例分析

Periprosthetic Femoral Fracture Is a Leading Cause of Early Revision With Taper-Slip Stems in Primary Total Hip Arthroplasty: An Analysis of 2765 Total Hip Arthroplasties From a High-Volume Hospital.
PubMed 文献 · J Arthroplasty · 2021-06-24

该研究比较了CPT与Exeter骨水泥股骨柄初次全髋置换后假体周围骨折(PFF)的翻修率。2年时PFF占所有翻修的35%,CPT柄PFF翻修率1.6%,Exeter柄1.0%;2周后CPT柄全因翻修风险显著高于Exeter柄(HR 1.8)。

要点

  • 2年时PFF是研究人群最常见的翻修原因,占所有翻修的35%。
  • CPT柄PFF翻修率1.6%,Exeter柄1.0%,锥形滑配柄PFF翻修数量值得关注。

核心结论

  • 锥形滑配股骨柄尤其CPT柄的PFF翻修数量较多,值得关注。
  • 对PFF高风险患者应考虑替代骨水泥柄。

研究设计与样本

  • 回顾性队列研究,纳入2012-2015年Exeter柄初次全髋1443例和2017-2018年CPT柄1322例。
  • 比较PFF翻修率,用Kaplan-Meier法估算假体生存率,用Cox比例风险回归分析翻修风险。

主要发现

  • 2年时PFF是最常见翻修原因,患病率1.3%,占所有翻修的35%。
  • CPT柄PFF翻修率1.6%(95%CI 1.0-2.4),Exeter柄1.0%(95%CI 0.6-1.6)。
  • 3年Kaplan-Meier全因翻修概率CPT柄4.8%(95%CI 3.6-6.0),Exeter柄3.3%(95%CI 2.3-4.3)。

临床怎么用

  • 对PFF高风险患者,选择骨水泥柄时应考虑替代锥形滑配设计。
  • 使用CPT柄时需关注2周后早期翻修风险,加强术后随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In 2016, the CPT stem replaced the Exeter stem as the main cemented stem at our institution. We assessed the prevalence of revision for periprosthetic femoral fracture (PFF) in patients operated on with either CPT or Exeter stem and compared the risk for revision between these stems. METHODS: Primary total hip arthroplasties either performed in 2012-2015 with Exeter stem (n = 1443) or in 2017-2018 with CPT stem (n = 1322) were included. The prevalence of revision for PFF was compared. The Kaplan-Meier estimated survivorships were calculated for the 2 stem designs. The risk for revision was analyzed using the Cox proportional hazard regression model. RESULTS: At 2 years, PFF was the most common reason for revision in the study population (1.3% prevalence, comprising 35% of all revisions). Moreover, 1.6% (95% confidence interval [CI] 1.0-2.4) of the CPT and 1.0% (95% CI 0.6-1.6) of the Exeter stems had been revised due to PFF. The 3-year Kaplan-Meier probability estimates for all-cause revision were 4.8% for the CPT (95% CI 3.6-6.0) and 3.3% for the Exeter stem (95% CI 2.3-4.3). The hazard ratio for revision due to any reason was 1.1 (95% CI 0.3-3.8) during the first 2 weeks, and 1.8 (95% CI 1.2-2.7, P = .006) from 2 weeks onwards for the CPT compared with the Exeter stem. CONCLUSION: The considerable number of PFF revisions with taper-slip stems, especially with CPT stems, is a matter of concern. Alternative cemented stems should be considered in patients at high risk for PFF.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pakarinen OA, Neuvonen PS, Lainiala OS, et al. Periprosthetic Femoral Fracture Is a Leading Cause of Early Revision With Taper-Slip Stems in Primary Total Hip Arthroplasty: An Analysis of 2765 Total Hip Arthroplasties From a High-Volume Hospital. J Arthroplasty. 2021. PMID: 34253441. doi:10.1016/j.arth.2021.06.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。