文献速递运动医学关节外科

3毫米厚真皮同种异体移植上囊重建在巨大后上肩袖缺损中部分恢复盂肱关节稳定性:动态机器人肩关节模型

Superior Capsule Reconstruction With a 3 mm-Thick Dermal Allograft Partially Restores Glenohumeral Stability in Massive Posterosuperior Rotator Cuff Deficiency: A Dynamic Robotic Shoulder Model.
PubMed 文献 · Am J Sports Med · 2021-06-03

结果发现,巨大后上肩袖撕裂会增加肱骨头向上平移,而SCR在静态和动态测试中均能部分恢复盂肱关节向上稳定性,但在低外展角度和低抬举角度下仍与完整状态存在差异。

要点

  • 巨大后上肩袖撕裂(冈上+冈下)较完整或单纯冈上撕裂增加肱骨头向上平移。
  • 3毫米厚真皮同种异体移植SCR在静态所有外展角度显著减少肱骨向上平移。
  • SCR在60°和90°外展时恢复至完整状态稳定性,但中立位和30°外展时仍显著上移。

核心结论

  • 在动态机器人肩关节模型中,3毫米厚真皮同种异体移植上囊重建可部分恢复模拟巨大后上肩袖撕裂后的盂肱关节向上稳定性。

研究设计与样本

  • 测试四种条件:完整、模拟不可修复冈上肌腱撕裂、模拟不可修复冈上-冈下肌腱撕裂、3毫米厚真皮同种异体移植SCR。
  • 静态测试为0°、30°、60°、90°外展下施加40牛向上力,动态测试为前屈、外展和肩胛平面抬举运动。

主要发现

  • 静态测试中,SCR在所有外展角度较肩袖撕裂状态显著减少肱骨向上平移。
  • SCR在60°和90°外展时恢复至完整状态稳定性,但中立位和30°外展时肱骨头仍显著向上平移。
  • 动态测试中,损伤状态在低抬举角度下向上平移显著增加,抬举>75°时差异无统计学意义。
  • SCR减少所有抬举角度的向上平移幅度,但抬举至60°时仍与完整状态显著不同。

关键数值与推荐

  • 静态测试采用40牛向上力,外展角度为0°、30°、60°、90°。
  • 动态测试评估前屈、外展和肩胛平面抬举运动,抬举角度>75°时损伤状态与完整状态差异无统计学意义。

临床怎么用

  • 对于巨大后上肩袖撕裂,SCR可能部分改善盂肱关节向上稳定性,尤其在较高外展角度。
  • 在低外展和低抬举角度,SCR后仍存在残余向上平移,临床需注意相应功能限制。

局限性

  • 本研究为尸体肩关节模型,不能完全反映活体生物学和软组织愈合过程。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Superior capsule reconstruction (SCR) has been shown to improve shoulder function and reduce pain in patients with isolated irreparable supraspinatus tendon tears. However, the effects of SCR on biomechanics in a shoulder with an extensive posterosuperior rotator cuff tear pattern remain unknown. PURPOSE/HYPOTHESIS: The purpose was to (1) establish a dynamic robotic shoulder model, (2) assess the influence of rotator cuff tear patterns, and (3) assess the effects of SCR on superior humeral head translation after a posterosuperior rotator cuff tear. It was hypothesized that a posterosuperior rotator cuff tear would increase superior humeral head translation when compared with the intact and supraspinatus tendon-deficient state and that SCR would reduce superior humeral head translation in shoulders with massive rotator cuff tears involving the supraspinatus and infraspinatus tendons. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve fresh-frozen cadaveric shoulders were tested using a robotic arm. Kinematic testing was performed in 4 conditions: (1) intact, (2) simulated irreparable supraspinatus tendon tear, (3) simulated irreparable supra- and infraspinatus tendon tear, and (4) SCR using a 3 mm-thick dermal allograft (DA). Kinematic testing consisted of static 40-N superior force tests at 0°, 30°, 60°, and 90° of abduction and dynamic flexion, abduction, and scaption motions. In each test, the superior translation of the humeral head was reported. RESULTS: In static testing, SCR significantly reduced humeral superior translation compared with rotator cuff tear at all abduction angles. SCR restored the superior stability back to native at 60° and 90° of abduction, but the humeral head remained significantly and superiorly translated at neutral position and at 30° of abduction. The results of dynamic testing showed a significantly increased superior translation in the injured state at lower elevation angles, which diminished at higher elevation, becoming nonsignificant at elevation >75°. SCR reduced the magnitude of superior translation across all elevation angles, but translation remained significantly different from the intact state up to 60° of elevation. CONCLUSION: Massive posterosuperior rotator cuff tears increased superior glenohumeral translation when compared with the intact and supraspinatus tendon-insufficient rotator cuff states. SCR using a 3-mm DA partially restored the superior stability of the glenohumeral joint even in the presence of a simulated massive posterosuperior rotator cuff tear in a static and dynamic robotic shoulder model. CLINICAL RELEVANCE: The biomechanical performance concerning glenohumeral stability after SCR in shoulders with large posterosuperior rotator cuff tears is unclear and may affect clinical outcomes in daily practice.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Lacheta L, Brady A, Rosenberg SI, et al. Superior Capsule Reconstruction With a 3 mm-Thick Dermal Allograft Partially Restores Glenohumeral Stability in Massive Posterosuperior Rotator Cuff Deficiency: A Dynamic Robotic Shoulder Model. Am J Sports Med. 2021. PMID: 34081548. doi:10.1177/03635465211013364

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。