文献速递运动医学关节外科

基于临床影像的前交叉韧带体外损伤模型

An Anterior Cruciate Ligament In Vitro Rupture Model Based on Clinical Imaging.
PubMed 文献 · Am J Sports Med · 2021-06-11

本研究用9对膝关节建立模拟临床骨挫伤模式的ACL体外损伤模型,并与关节镜下ACL横断对比。ACL损伤在26±5 mm前向平移和1550±620 N力下断裂,导致的松弛度大于横断,且重建后残余松弛更明显。

要点

  • ACL损伤模型在22.5°屈曲、5°内旋、710 N关节压力下复制临床骨挫伤模式。
  • ACL损伤后重建的残余松弛持续至40°,而横断后重建仅至20°。

核心结论

  • ACL损伤模型成功复制临床ACL损伤的骨挫伤模式,损伤导致的松弛度大于单纯横断,且重建后差异常持续存在。

研究设计与样本

  • 控制性实验室研究,采用9对配对膝关节,一侧行ACL损伤(模拟临床骨挫伤模式),对侧行关节镜下ACL横断,两组均行骨-髌腱-骨重建。

主要发现

  • ACL在26±5 mm前向平移和1550±620 N力下断裂,伴有可闻及的胫股回弹撞击和5°外翻。
  • ACL损伤和横断均增加前向平移(P<.001),损伤比横断多1.4 mm(范围0.4-2.2 mm,P=.033)。
  • 内旋在损伤膝0°-30°屈曲和横断膝0°-20°屈曲显著增加。
  • 前向平移+内旋 maneuver中,损伤膝0°-80°和横断膝0°-60°前向平移增加。
  • 重建后残余松弛:损伤膝0°-40°,横断膝0°-20°;轴移试验中损伤膝0°-50°和横断膝0°-20°前向平移显著增加,重建后持续至0°-40°和0°-20°。

关键数值与推荐

  • ACL损伤模型参数:22.5°屈曲、5°内旋、710 N关节压力、1000 mm/min胫骨前向平移速度。
  • ACL断裂时前向平移26±5 mm,力1550±620 N(均值±标准差)。
  • 损伤与横断前向平移差异1.4 mm(范围0.4-2.2 mm,P=.033)。

临床怎么用

  • 该体外模型比手术横断更真实地模拟ACL损伤,可用于未来评估ACL重建技术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Biomechanical studies on anterior cruciate ligament (ACL) injuries and reconstructions are based on ACL transection instead of realistic injury trauma. PURPOSE: To replicate an ACL injury in vitro and compare the laxity that occurs with that after an isolated ACL transection injury before and after ACL reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: Nine paired knees were ACL injured or ACL transected. For ACL injury, knees were mounted in a rig that imposed tibial anterior translation at 1000 mm/min to rupture the ACL at 22.5° of flexion, 5° of internal rotation, and 710 N of joint compressive force, replicating data published on clinical bone bruise locations. In contralateral knees, the ACL was transected arthroscopically at midsubstance. Both groups had ACL reconstruction with bone-patellar tendon-bone graft. Native, ACL-deficient, and reconstructed knee laxities were measured in a kinematics rig from 0° to 100° of flexion with optical tracking: anterior tibial translation (ATT), internal rotation (IR), anterolateral (ATT + IR), and pivot shift (IR + valgus). RESULTS: The ACL ruptured at 26 ± 5 mm of ATT and 1550 ± 620 N of force (mean ± SD) with an audible spring-back tibiofemoral impact with 5o of valgus. ACL injury and transection increased ATT (P < .001). ACL injury caused greater ATT than ACL transection by 1.4 mm (range, 0.4-2.2 mm; P = .033). IR increased significantly in ACL-injured knees between 0° and 30° of flexion and in ACL transection knees from 0° to 20° of flexion. ATT during the ATT + IR maneuver was increased by ACL injury between 0° and 80° and after ACL transection between 0° and 60°. Residual laxity persisted after ACL reconstruction from 0° to 40° after ACL injury and from 0° to 20° in the ACL transection knees. ACL deficiency increased ATT and IR in the pivot-shift test (P < .001). The ATT in the pivot-shift increased significantly at 0° to 20° after ACL transection and 0° to 50° after ACL injury, and this persisted across 0° to 20° and 0° to 40° after ACL reconstruction. CONCLUSION: This study developed an ACL injury model in vitro that replicated clinical ACL injury as evidenced by bone bruise patterns. ACL injury caused larger increases of laxity than ACL transection, likely because of damage to adjacent tissues; these differences often persisted after ACL reconstruction. CLINICAL RELEVANCE: This in vitro model created more realistic ACL injuries than surgical transection, facilitating future evaluation of ACL reconstruction techniques.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Willinger L, Athwal KK, Williams A, et al. An Anterior Cruciate Ligament In Vitro Rupture Model Based on Clinical Imaging. Am J Sports Med. 2021. PMID: 34115540. doi:10.1177/03635465211017145

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。