文献速递关节外科

滑膜液α防御素诊断假体周围关节感染的准确性

Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis.
PubMed 文献 · Bone Joint J · 2021-01-01

本研究纳入99例全髋或全膝关节置换术后疼痛行关节穿刺的患者,比较滑膜液α防御素侧流法和ELISA与白细胞计数及中性粒细胞百分比的诊断准确性。以专家共识诊断为参考标准,α防御素侧流法敏感度83.3%、特异度93.8%,ELISA敏感度83.3%、特异度96.3%,与白细胞计数联合中性粒细胞百分比联合应用相比无统计学优势。

要点

  • α防御素侧流法诊断假体周围关节感染敏感度83.3%、特异度93.8%。
  • α防御素ELISA敏感度83.3%、特异度96.3%。
  • α防御素诊断准确性不优于滑膜白细胞计数联合中性粒细胞百分比。

核心结论

  • 滑膜液α防御素诊断假体周围关节感染的准确性与传统滑膜白细胞计数联合中性粒细胞百分比相当,无统计学优势。

研究设计与样本

  • 纳入99例全髋或全膝关节置换术后疼痛行关节穿刺患者的滑膜液,分析白细胞计数、中性粒细胞百分比、α防御素侧流法和ELISA。
  • 由三名骨科感染专家盲法独立评审患者数据,以共识分类为参考标准。

主要发现

  • 专家共识将18例关节成形术归为假体周围关节感染失败,81例归为无菌性失败。
  • α防御素侧流法敏感度83.3%(95%CI 58.6-96.4)、特异度93.8%(95%CI 86.2-98.0),AUC为0.891。
  • α防御素ELISA敏感度83.3%(95%CI 58.6-96.4)、特异度96.3%(95%CI 89.6-99.2)。
  • 两种α防御素检测方法间敏感度(p=1.000)和特异度(p=0.157)无统计学差异。
  • 滑膜白细胞计数AUC为0.821(敏感度p=1.000,特异度p<0.001),中性粒细胞百分比AUC为0.886(敏感度p=0.317,特异度p=0.011),两者联合AUC为0.926(敏感度p=0.317,特异度p=0.317)。

关键数值与推荐

  • 全膝关节置换术白细胞计数 cutoff 为≥1,700 cells/mm3,中性粒细胞百分比 cutoff 为≥65%。
  • 全髋关节置换术白细胞计数 cutoff 为≥3,000 cells/mm3,中性粒细胞百分比 cutoff 为≥80%。

临床怎么用

  • 滑膜液α防御素可作为假体周围关节感染诊断的辅助检测,但其准确性未超越白细胞计数联合中性粒细胞百分比。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. METHODS: Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar's test and area under the receiver operating characteristic curve (AUC) analysis. RESULTS: Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. CONCLUSION: The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119-1126.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Ivy MI, Sharma K, Greenwood-Quaintance KE, et al. Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis. Bone Joint J. 2021. PMID: 34058872. doi:10.1302/0301-620X.103B6.BJJ-2020-1741.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。