全髋关节置换中双动与大口径股骨头假体的翻修率比较
基于澳大利亚骨科协会国家关节置换登记系统2008年至2019年因骨关节炎行初次全髋关节置换的106,163例数据,比较双动(DM)与大口径股骨头假体(≥36 mm)因脱位和无菌性原因的翻修率。
要点
- DM与大口径股骨头假体在初次全髋中脱位及无菌性翻修率无显著差异。
- 髋臼杯直径≥58 mm时,DM与大口径股骨头脱位翻修率无差异。
核心结论
- 初次全髋关节置换中,双动与大口径股骨头假体在脱位翻修率和无菌性翻修率上无差异。
- 按髋臼杯直径分层,双动假体在直径<58 mm时降低脱位翻修率。
研究设计与样本
- 基于澳大利亚骨科协会国家关节置换登记系统的回顾性队列分析,纳入2008年1月至2019年12月因骨关节炎行初次全髋关节置换的患者。
- 共分析106,163例初次全髋关节置换,其中双动假体4,942例,大口径股骨头假体(≥36 mm)101,221例。
- 主要结局为脱位和无菌性原因的累积翻修百分比,结果按年龄、性别和股骨固定方式调整。
- 按髋臼杯直径<58 mm和≥58 mm进行亚组分析。
主要发现
- 髋臼杯直径≥58 mm时,双动与大口径股骨头假体脱位翻修率无差异。
- 按髋臼杯直径分层,无菌性翻修率无差异。
临床怎么用
- 在初次全髋关节置换中,双动与大口径股骨头假体在脱位和无菌性翻修风险上总体相当。
- 对于髋臼杯直径<58 mm的患者,可考虑选用双动假体以降低脱位翻修风险。
- 髋臼杯直径≥58 mm时,双动与大口径股骨头假体的脱位翻修风险无差异。
局限性
- 本研究为登记系统回顾性分析,证据等级为Level III。
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Dual mobility (DM) and large femoral head bearings (≥36 mm) both decrease the risk of dislocation in total hip arthroplasty (THA). There is limited comparable data in primary THA. This study compared the revision rates for dislocation and aseptic causes between DM and large femoral heads and subanalyzed by acetabular component size. METHODS: Data from the Australian Orthopedic Association National Joint Replacement Registry were analyzed for patients undergoing primary THA for osteoarthritis from January 2008 (the year of first recorded DM use) to December 2019. All DM and large femoral head bearings were identified. The primary outcome measure was the cumulative percent revision (CPR) for dislocation and for all aseptic causes. The results were adjusted by age, sex, and femoral fixation. A subanalysis was performed stratifying acetabular component diameter <58 m and ≥58 mm. RESULTS: There were 4942 DM and 101,221 large femoral head bearings recorded. There was no difference in the CPR for dislocation (HR = 0.69 (95% CI 0.42, 1.13), P = .138) or aseptic causes (HR = 0.91 (95% CI 0.70, 1.18), P = .457). When stratified by acetabular component size, DM reduced the CPR for dislocation in acetabular component diameter <58 mm (HR = 0.55 (95% CI 0.30, 1.00), P = .049). There was no difference for diameter ≥58 mm. There was no difference in aseptic revision when stratified by acetabular component diameter. CONCLUSION: There is no difference in revision rates for dislocation or aseptic causes between DM and large femoral heads in primary THA. When stratified by acetabular component size, DM reduces dislocation for acetabular component diameter <58 mm. LEVEL OF EVIDENCE: Level III.
引用
- Hoskins W, Bingham R, Dyer C, et al. A Comparison of Revision Rates for Dislocation and Aseptic Causes Between Dual Mobility and Large Femoral Head Bearings in Primary Total Hip Arthroplasty With Subanalysis by Acetabular Component Size: An Analysis of 106,163 Primary Total Hip Arthroplasties. J Arthroplasty. 2021. PMID: 34088570. doi:10.1016/j.arth.2021.05.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。