MALDI-TOF MS检测滑液α防御素诊断假体周围关节感染的准确性与成本效益
该研究纳入138例全膝/全髋关节置换失败患者,以2018年MSIS标准诊断PJI,评估MALDI-TOF MS检测滑液α防御素的诊断效能。结果显示总体准确率94.9%,敏感度93%、特异度96%,AUC为0.95(P<.001),提示该检测对PJI诊断具有高敏感性和特异性。
要点
- MALDI-TOF MS检测滑液α防御素诊断PJI的总体准确率为94.9%。
- 敏感度93%、特异度96%,阳性预测值和阴性预测值均为95%。
- ROC曲线下面积为0.95(P<.001),支持该检测用于PJI诊断。
核心结论
- MALDI-TOF MS检测滑液α防御素在全膝/全髋关节置换失败病例中表现出高敏感性和特异性。
- 该技术所需样本量少、结果获取快且具有成本效益,可能成为临床广泛应用的检测方法。
研究设计与样本
- 研究纳入138例全膝/全髋关节置换失败患者,采用2018年MSIS标准诊断PJI。
- 对滑液进行常规检测及MALDI-TOF MS法α防御素检测,计算敏感度、特异度、总体诊断准确率、阳性及阴性预测值、ROC曲线和曲线下面积。
主要发现
- 按2018年MSIS标准,诊断59例PJI(43%)和79例无菌性失败(57%)。
- MALDI-TOF MS检测的总体准确率为94.9%,敏感度93%,特异度96%。
- 阳性预测值为95%,阴性预测值为95%,ROC曲线下面积为0.95(P<.001)。
关键数值与推荐
- 以2018年MSIS标准为参考诊断PJI。
- MALDI-TOF MS检测滑液α防御素诊断PJI:总体准确率94.9%,敏感度93%,特异度96%,阳性预测值95%,阴性预测值95%,AUC 0.95(P<.001)。
临床怎么用
- 对于全膝/全髋关节置换失败疑似PJI的患者,可考虑采用MALDI-TOF MS检测滑液α防御素辅助诊断。
- 该检测样本量少、出结果快,可能有助于临床快速决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Two methods for detecting synovial fluids alpha defensins are available: the enzyme-linked immunosorbent assay and the lateral flow test. For both, the proper role and accuracy remain uncertain. The purpose of this study was to assess the accuracy of the matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) for alpha defensin detection in synovial fluids of patients with total knee arthroplasty/total hip arthroplasty failures. The hypothesis was that the alpha defensin measurement through MALDI-TOF MS assay could be a high sensitive and specific test for periprosthetic joint infections (PJI) diagnosis as compared with Musculoskeletal Infection Society (MSIS) criteria. METHODS: The study included 138 patients. The 2018 MSIS criteria were used to diagnose PJIs. Synovial fluids were assessed for routinely synovial fluid tests and alpha defensin measurement through MALDI-TOF MS. Sensitivity, specificity, overall diagnostic accuracy, positive and negative predictive values, receiver operator curves, and area under the curve were calculated. RESULTS: As per the 2018 MSIS criteria, 59 PJIs (43%) and 79 aseptic failures (57%) were diagnosed. The MALDI-TOF MS assay showed an overall accuracy of 94.9%. The sensitivity was 93%, the specificity was 96%, the positive predictive value was 95%, and the negative predictive value was 95%. Receiver operator curves analysis demonstrates an area under the curve of 0.95 (P < .001). CONCLUSION: The MALDI-TOF MS assay showed high sensitivity and specificity for alpha defensin detection in case of total knee arthroplasty/total hip arthroplasty failures. The advantages of the technology, such as the few milliliters of sample needed, the rapidity of obtaining results, and the cost-effectiveness of the procedure could make the MALDI-TOF MS alpha defensin assay a useful and widespread test in clinical practice.
引用
- Iorio R, Viglietta E, Mazza D, et al. Accuracy and Cost-Effectivenss of a Novel Method for Alpha Defensins Measurement in the Diagnosis of Periprosthetic Joint Infections. J Arthroplasty. 2021. PMID: 34088569. doi:10.1016/j.arth.2021.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。