全髋关节置换术中的肢体长度差异:小转子是可靠的长度测量参考吗?
结果显示约六分之一患者存在>10 mm的肢体长度差异(LLD),LT与COH测量结果相似,提示两种常用股骨参考点均需考虑下肢骨骼长度变异对LLD评估的影响。
要点
- 以LT或COH为参考点,约1/6患者LLD>10 mm。
- 股骨长度平均434.0 mm,胫骨长度平均379.9 mm。
- 女性与股骨长度不对称百分比增加相关(P=.037)。
核心结论
- 以LT或COH为参考点测量时,约六分之一患者LLD>10 mm。
- 使用LT或COH在骨盆X线片上估算LLD的术者,规划髋关节重建时应考虑下肢骨骼长度变异。
研究设计与样本
- 分别以股骨头中心(COH)和小转子(LT)为近端参考点测量双侧腿长、股骨长度和胫骨长度。
主要发现
- 股骨长度平均434.0±39.8 mm(侧别差异MD 4.3±3.5 mm),胫骨长度平均379.9±34.6 mm(MD 5.9±12.7 mm)。
- COH-距骨长度平均817.5±73.2 mm(MD 6.4±5.1 mm),LT-距骨长度平均760.5±77.6 mm(MD 5.8±5.1 mm)。
- 绝对不对称>10 mm者:COH-距骨为16%,LT-距骨为15%。
- 不对称百分比>1.5%者:COH-距骨为13%,LT-距骨为18%。
- 女性与股骨长度不对称百分比增加相关(P=.037)。
关键数值与推荐
- LLD绝对不对称>10 mm定义为阳性:COH-距骨16%,LT-距骨15%。
- 不对称百分比>1.5%定义为阳性:COH-距骨13%,LT-距骨18%。
临床怎么用
- 术前使用LT或COH在骨盆X线片上估算LLD时,应认识到约1/6患者可能存在>10 mm的真实LLD。
- 规划全髋关节置换术髋关节重建时,需考虑股骨和胫骨长度变异对LLD评估的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Limb length discrepancy (LLD) after total hip arthroplasty may affect clinical outcomes and patient satisfaction. Preoperative LLD estimates on anteroposterior pelvic radiographs fail to account for anatomical limb variation distal to the femoral reference points. The objective of this study is to determine how variations in lower limb skeletal lengths contribute to true LLD. METHODS: Full-length standing anteroposterior radiographs were used to measure bilateral leg length, femoral length, and tibial length. Leg length was evaluated using 2 different proximal reference points: the center of the femoral head (COH) and the lesser trochanter (LT). Mean side-to-side discrepancy (MD) and percentage asymmetry (%AS) for each measurement were evaluated in the overall cohort and when stratified by patient demographic variables. RESULTS: One hundred patients were included with an average age of 62.9 ± 11.2 years. Average femoral length was 434.0 ± 39.8 mm (MD 4.3 ± 3.5 mm) and tibial length was 379.9 ± 34.6 mm (MD 5.9 ± 12.7 mm). Average COH-talus was 817.5 ± 73.2 mm (MD 6.4 ± 5.1 mm). Average LT-talus was 760.5 ± 77.6 mm (MD 5.8 ± 5.1 mm). Absolute asymmetry >10 mm was detected in 16% of patients for COH-talus and 15% for LT-talus, while %AS >1.5% was detected in 13% of patients for COH-talus and 18% for LT-talus. Female gender was associated with increased femoral length %AS (P = .037). CONCLUSION: Approximately 1 in 6 patients have an LLD of >10 mm when measured from either the LT or COH. Surgeons using either of these common femoral reference points to estimate LLD on pelvic radiographs should consider these findings when planning for hip reconstruction. LEVEL OF EVIDENCE: Level III.
引用
- Gallo MC, Chung BC, Tucker DW, et al. Limb Length Discrepancy in Total Hip Arthroplasty: Is the Lesser Trochanter a Reliable Measure of Leg Length? J Arthroplasty. 2021. PMID: 34183211. doi:10.1016/j.arth.2021.06.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。