现代初次非骨水泥股骨柄在翻修髋关节置换术中的作用
本研究回顾性比较70例Paprosky I或II型股骨骨缺损翻修THA患者,35例使用初次非骨水泥股骨柄,35例使用翻修型骨干固定柄。平均随访2.9年,两组在并发症、影像学结果和患者报告结局上无显著差异,无股骨假体再翻修。结论认为在近端股骨干骺端骨保留时,现代初次非骨水泥柄是可行选择。
要点
- Paprosky I/II型股骨骨缺损翻修THA,初次非骨水泥柄与翻修柄临床和影像学结果无显著差异。
- 两组假体下沉、腿长差异和HOOS-Jr评分差异均无统计学意义。
- 无患者因股骨假体问题接受再翻修手术。
核心结论
- 在近端股骨干骺端骨保留的翻修THA中,使用现代初次非骨水泥股骨柄是可行选择,结局不劣于翻修柄。
研究设计与样本
- 回顾性分析70例Paprosky I或II型股骨骨缺损行股骨翻修的患者,35例使用初次非骨水泥股骨柄,35例使用翻修型骨干固定柄,平均随访2.9年(SD 1.4)。
主要发现
- 翻修THA最常见原因为假体周围关节感染(N=27,38.6%)。
- 无患者接受涉及股骨假体的再翻修手术。
关键数值与推荐
- Paprosky I或II型股骨骨缺损是使用初次非骨水泥股骨柄的解剖条件。
临床怎么用
- 对于近端股骨干骺端骨保留的翻修THA,可考虑使用现代初次非骨水泥股骨柄作为翻修柄的替代选项。
局限性
- 本研究为回顾性分析,样本量70例,平均随访2.9年(SD 1.4),可能影响长期结论的可靠性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated "primary" femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem. METHODS: This was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4). RESULTS: Revision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component. CONCLUSION: Use of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits.
引用
- Skibicki HE, Post ZD, Kay AB, et al. A Role for Modern Primary Cementless Femoral Stems in Revision Hip Arthroplasty. J Arthroplasty. 2021. PMID: 34053749. doi:10.1016/j.arth.2021.04.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。