文献速递关节外科

DAIR治疗假体周围感染:成功与失败的预测因素

Debridement, Antibiotics, and Implant Retention in Periprosthetic Joint Infection: What Predicts Success or Failure?
PubMed 文献 · J Arthroplasty · 2021-05-24

该研究回顾性分析了106例DAIR治疗假体周围感染病例,成功率为69.8%。甲氧西林敏感金黄色葡萄球菌感染、术前ESR>107.5及重复DAIR与治疗失败显著相关,建议对失败高风险患者行二期翻修。

要点

  • DAIR治疗PJI的成功率为69.8%(74/106)。
  • 甲氧西林敏感金黄色葡萄球菌感染是DAIR失败的显著预测因素(OR 3.64)。
  • 术前ESR>107.5及重复DAIR与失败强相关,建议二期翻修。

核心结论

  • DAIR失败与更短的DAIR至死亡时间相关。
  • 重复DAIR、术前ESR>107.5和金黄色葡萄球菌PJI与治疗失败相关,推荐二期翻修。

研究设计与样本

  • 回顾性综述106例DAIR病例,失败定义为需移除TKA假体。

主要发现

  • DAIR成功率为69.8%(74/106)。

关键数值与推荐

  • ESR>107.5预测失败,敏感性51.5,特异性85.2。

临床怎么用

  • 对于术前ESR>107.5、重复DAIR或金黄色葡萄球菌PJI患者,应考虑二期翻修而非DAIR。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Debridement, antibiotics and implant retention (DAIR) is the treatment of choice for acute postoperative and acute hematogenous periprosthetic joint infection (PJI). There is limited literature on predictive prognostic factors for DAIR. We aim to report the outcomes of DAIR and investigate the predictive prognostic factors. METHODS: We retrospectively reviewed 106 DAIRs. Failure was defined as requiring removal of TKA implants. Predictive factors that may influence success of DAIR treatment such as age, gender, body mass index, ethnicity, American Society of Anesthesiologists score, comorbidities, preoperative erythrocyte sedimentation rate (ESR) and C-reactive protein, symptom duration, time between total knee arthroplasty and DAIR, cultures, rifampicin use, polyethylene liner change, and antibiotic duration were analyzed. RESULTS: The success rate of DAIR was 69.8% (74/106 patients). For successes, mean time from DAIR-to-mortality was longer than failures (61.6 ± 42.7 vs 9.75 ± 9.60 months, P = .0150). Methicillin-susceptible Staphylococcus aureus PJI (odds ratio [OR] 3.64, confidence interval [CI] 1.30-10.2, P = .0140) was a significant predictor for failure of DAIR. Higher preoperative ESR correlated to failure (OR 1.02, CI 1.01-1.04, P = .008). In successes, mean ESR was 75.4 (66.1-84.6), whereas mean ESR in failures was 116 (88.3-143) (P = .011). An ESR > 107.5 predicted failure with a sensitivity of 51.5 and specificity of 85.2. ESR > 107.5 correlated to failure (OR 6.60, CI 2.29-19.0, P < .001). Repeat DAIRs were strongly correlated to failure (OR 5.27, CI 1.99-13.9, P < .01). CONCLUSION: DAIR failure is associated with earlier time to mortality. Repeat DAIRs, elevated ESR > 107.5, and S aureus PJI are associated with treatment failure and 2-stage revision is recommended.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Toh RX, Yeo ZN, Liow MHL, et al. Debridement, Antibiotics, and Implant Retention in Periprosthetic Joint Infection: What Predicts Success or Failure? J Arthroplasty. 2021. PMID: 34116912. doi:10.1016/j.arth.2021.05.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。