Vancouver C型假体周围股骨骨折的治疗结果
本研究回顾性分析42例Vancouver C型假体周围股骨骨折,均采用外侧锁定钢板治疗。结果显示90天死亡率为5%,2年死亡率为31%;2年再手术累积发生率为13%,骨不连累积发生率为10%。
要点
- Vancouver C型假体周围股骨骨折患者2年死亡率高达31%。
- 外侧锁定钢板治疗后2年再手术累积发生率为13%。
- 再手术最常见原因为感染或骨不连。
核心结论
- Vancouver C型假体周围股骨骨折患者2年死亡率为31%,2年内13%需再手术,最常见原因为感染或骨不连。
研究设计与样本
- 回顾性队列研究,纳入2004年至2018年间42例连续Vancouver C型假体周围股骨骨折,均采用外侧锁定钢板治疗。
主要发现
- 患者90天死亡率为5%,2年死亡率为31%。
- 2年再手术累积发生率为13%,共5例再手术:骨不连和/或内固定失败行翻修2例,感染行清创及内固定取出2例,创伤后关节炎行内固定取出及全膝关节置换1例。
- 2年骨不连累积发生率为10%。
关键数值与推荐
- 98%病例的固定跨越了股骨假体,18%病例固定近端延伸至小转子。
- 平均随访时间为2年。
临床怎么用
- 对于Vancouver C型假体周围股骨骨折,采用外侧锁定钢板治疗时需关注高死亡率及再手术风险,再手术常见原因为感染和骨不连。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Periprosthetic femur fractures (PFFs) that occur distal to a total hip arthroplasty, Vancouver C fractures, are challenging to treat. We aimed to report patient mortality, reoperations, and complications following Vancouver C PFFs in a contemporary cohort all treated with a laterally based locking plate. METHODS: We retrospectively identified 42 consecutive Vancouver C PFFs between 2004 and 2018. There was a high prevalence of comorbidities, including 9 patients with neurologic conditions, 9 with a history of cancer, 8 diabetics, and 8 using chronic anticoagulation. Mean time from total hip arthroplasty to PFF was 6 years (range 1 month to 25 years). All fractures were treated with a laterally based locking plate. Fixation bypassed the femoral component in 98% of cases and extended as proximal as the lesser trochanter in 18%. Kaplan-Meier survival was used for patient mortality, and a competing risk model was used to analyze survivorship free of reoperation and nonunion. Mean follow-up was 2 years. RESULTS: Patient mortality was 5% at 90 days and 31% at 2 years. Cumulative incidence of reoperation was 13% at 2 years. There were 5 reoperations including revision osteosynthesis for nonunion and/or hardware failure (2), debridement and hardware removal for infection (2), and removal of hardware and total knee arthroplasty for post-traumatic arthritis (1). Cumulative incidence of nonunion was 10% at 2 years. CONCLUSION: Patients who sustained a Vancouver C PFFs had a high mortality rate (31%) at 2 years. Moreover, 13% of patients required a reoperation within 2 years, most commonly for infection or nonunion.
引用
- Gausden EB, Tibbo ME, Perry KI, et al. Outcomes of Vancouver C Periprosthetic Femur Fractures. J Arthroplasty. 2021. PMID: 34119395. doi:10.1016/j.arth.2021.05.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。