定制三翼杯:20年经验
本研究回顾了2000年至2018年间50例使用定制三翼杯行翻修全髋关节置换术的患者,评估假体生存率、再手术、并发症及临床结局。定制三翼杯是处理复杂髋臼缺损的可靠方案,但需告知患者手术规模大及并发症发生率高。
要点
- 定制三翼杯翻修THA后平均HHS提高24分,91%患者满意。
- 主要并发症发生率28%,脱位最常见(12%)。
- 再手术2例(急性感染和螺钉取出各1例)。
核心结论
- 定制三翼杯是处理翻修THA中复杂髋臼缺损的可靠解决方案。
- 应告知患者手术规模大及并发症(尤其感染和脱位)发生率高。
研究设计与样本
- 前瞻性收集2000年1月至2018年12月50例使用三翼杯行翻修THA的患者数据。
- 94%的病例有已知结局或至少两年随访。
- 对近期随访超过2年的患者进行电话访谈,并进行影像学复查以定义假体稳定或不稳定。
主要发现
- 91%的合格患者在随访时满意。
- 主要并发症14例(28%),脱位最常见(12%)。
- 再手术2例(1例急性感染,1例螺钉取出)。
- 46%(23/50)的患者存在Trendelenburg步态。
关键数值与推荐
- 91%的合格患者在随访时满意。
- 主要并发症发生率为28%(14例)。
- 脱位发生率为12%。
- Trendelenburg步态发生率为46%(23/50)。
临床怎么用
- 定制三翼杯可用于翻修THA中复杂髋臼缺损的重建。
- 术前应告知患者手术规模大及并发症发生率高,特别是感染和脱位。
局限性
- 样本量较小(50例)。
- 94%的病例有已知结局或至少两年随访,部分失访。
- 电话访谈用于部分患者随访,可能存在信息偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The custom triflange acetabular component is used during revision THA to address severe acetabular bone loss. Midterm results are promising, with low rates of loosening and triflange revision reported. However, reoperation and overall complication rates remain high. We aim to investigate our institution's custom triflange experience over 20 years by evaluating implant survivorship, reoperations, complications, and clinical outcomes. METHODS: Prospectively collected data were reviewed for 50 patients undergoing revision THA with the use of a triflanged component from January 2000 to December 2018. 94% among these cases had a known outcome or minimum two year follow-up. Outcomes related to the triflange component were recorded, including revisions, reoperations, surgical complications, medical complications, Harris hip scores, and patient satisfaction. Phone interviews were conducted with patients whose recent follow-up exceeded 2 years. Radiographic review was performed to define implants as either stable or unstable. RESULTS: The average Harris hip scores improved 24 points (49 to 73; P < .001). 91% of eligible patients were satisfied at follow-up. One patient was scheduled for revision at an outside institution during the study period. There were 2 reoperations (1 acute infection and 1 screw removal). One patient died due to pulmonary thromboembolism. A Trendelenberg gait was present in 46% (23/50) of patients. There were 14 major complications (28%). Dislocation (12%) was the most common complication. CONCLUSION: Custom triflange components provide a reliable solution for managing complex acetabular defects in revision THA. Patients should be counseled on magnitude of surgery and the high incidence of complications, specifically infection and dislocation.
引用
- Sershon RA, McDonald JF, Nagda S, et al. Custom Triflange Cups: 20-Year Experience. J Arthroplasty. 2021. PMID: 34074542. doi:10.1016/j.arth.2021.05.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。