后路腰椎手术后13周大鼠椎旁肌生物力学特性的变化
本研究在12只Sprague-Dawley大鼠中比较了后路腰椎手术(剥离椎旁肌)与假手术对椎旁肌生物力学特性的影响。术后13周,多裂肌纤维束的弹性模量在手术组显著高于假手术组(中位数82 kPa vs 38 kPa,P=0.0004),且多裂肌I型胶原沉积显著增加(中位数20.8% vs 5.8%,P<0.0001)。结论认为手术损伤增加了多裂肌纤维束的被动刚度,细胞外基质胶原增加可能是原因。
要点
- 后路腰椎手术损伤后13周,大鼠多裂肌纤维束被动刚度显著增加。
- 多裂肌I型胶原沉积显著增多,可能是刚度增加的原因。
- 多裂肌和最长肌单纤维及最长肌纤维束的弹性模量无显著差异。
核心结论
- 手术损伤增加了多裂肌纤维束的被动刚度,细胞外基质胶原含量增加可能是原因,这些变化可能对术后脊柱代偿有重要意义。
研究设计与样本
- 临床前动物研究,12只Sprague-Dawley大鼠均分为假手术组和手术损伤组,术后13周取右侧L1、L3、L5水平多裂肌和最长肌活检进行力学测试和组织学检查。
主要发现
- 多裂肌和最长肌单纤维及最长肌纤维束的弹性模量在手术组与假手术组间无显著差异。
- 多裂肌纤维束弹性模量手术组显著高于假手术组(中位数82 kPa,范围23-284;假手术组中位数38 kPa,范围23-50;P=0.0004)。
- 手术组多裂肌纤维束弹性模量在不同脊柱水平间无统计学差异(P=0.023)。
- 组织学显示仅多裂肌I型胶原沉积在手术组显著增加(中位数20.8% vs 假手术组5.8%,P<0.0001)。
关键数值与推荐
- 共测试220根纤维和279束纤维束。
- 非参数统计方法,显著性水平为1.25%。
临床怎么用
- 后路腰椎手术可能增加多裂肌纤维束的被动刚度,提示术中应尽量减少椎旁肌损伤以保护其生物力学特性。
局限性
- 研究为动物模型,样本量较小(12只大鼠),结果外推至人类需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Preclinical study in rodents. OBJECTIVE: To investigate changes in biomechanical properties of paraspinal muscles following a posterior spinal surgery in an animal model. SUMMARY OF BACKGROUND DATA: Posterior spine surgery damages paraspinal musculature per histological and imaging studies. The biomechanical effects of these changes are unknown. METHODS: 12 Sprague-Dawley rats were divided equally into sham and surgical injury (SI) groups. For sham, the skin and lumbodorsal fascia were incised at midline. For SI, the paraspinal muscles were detached from the vertebrae, per normal procedure. Thirteen weeks postsurgery, multifidus and longissimus biopsies at L1, L3, and L5 levels were harvested on the right. From each biopsy, three fibers and three to six bundles of fibers (∼10-20 fibers ensheathed in their extracellular matrix) were tested mechanically to measure their passive elastic modulus. The collagen content and fatty infiltration of each biopsy were also examined histologically by immunofluorescence staining. Nonparametric statistical methods were used with a 1.25% level of significance. RESULTS: A total of 220 fibers and 279 bundles of fibers were tested. The elastic moduli of the multifidus and longissimus fibers and longissimus fiber bundles were not significantly different between the SI and sham groups. However, the elastic modulus of multifidus fiber bundles was significantly greater in the SI group compared to sham (SI median 82 kPa, range 23-284; sham median 38 kPa, range 23-50, P = 0.0004). The elastic modulus of multifidus fiber bundles in the SI group was not statistically different between spinal levels (P = 0.023). For histology, only collagen I deposition in multifidus was significantly greater in the SI group (median 20.8% vs. 5.8% for sham, P < 0.0001). CONCLUSION: The surgical injury increased the passive stiffness of the multifidus fiber bundles. Increased collagen content in the extracellular matrix is the likely reason and these changes may be important in the postoperative compensation of the spine.Level of Evidence: N/A.
引用
- Yamamoto S, Malakoutian M, Theret M, et al. The Effect of Posterior Lumbar Spinal Surgery on Biomechanical Properties of Rat Paraspinal Muscles 13 Weeks After Surgery. Spine (Phila Pa 1976). 2021. PMID: 34156788. doi:10.1097/BRS.0000000000004036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。