全膝关节翻修术中孤立胫骨垫片更换的疗效:磨损可靠耐用,不稳定、垫片骨折/脱位或僵硬较差

Isolated tibial insert exchange in revision total knee arthroplasty : reliable and durable for wear; less so for instability, insert fracture/dissociation, or stiffness.
PubMed 文献 · Bone Joint J · 2021-01-01

本研究回顾1985至2016年单中心270例孤立胫骨垫片更换(ITIE),主要适应症为不稳定(55%)、聚乙烯磨损(39%)、垫片骨折/脱位(5%)和僵硬(1%)。10年无再翻修生存率总体68%,磨损组74%;非磨损适应症再翻修风险更高(HR 1.9; p=0.013),不稳定组10年生存率69%,垫片骨折/脱位组37%。

要点

  • 孤立胫骨垫片更换10年无再翻修生存率总体68%,磨损组74%。
  • 非磨损适应症再翻修风险显著更高(HR 1.9; p=0.013)。
  • 非磨损适应症失败模式多为原诊断复发,磨损组多为无菌性松动。

核心结论

  • ITIE后再翻修的风险和原因与术前适应症相关,聚乙烯磨损结果最佳,其他诊断再翻修率更高且失败模式常为原适应症复发。

研究设计与样本

  • 1985至2016年单中心回顾性研究,共270例孤立胫骨垫片更换,排除组件松动、假体位置不良、感染和伸膝装置问题。

主要发现

  • 总体10年无任何再翻修生存率为68%。
  • 磨损适应症10年无任何再翻修生存率为74%。
  • 非磨损适应症再翻修更频繁(HR 1.9; p=0.013),不稳定10年生存率69%,垫片骨折/脱位37%。
  • 磨损组再翻修最常见原因为无菌性松动(33%, n=7),其他适应症最常见原因为原诊断复发。
  • 平均膝关节协会评分从术前54(0至94)改善至10年时77(38至94)。

临床怎么用

  • 对于聚乙烯磨损为主的翻修,孤立胫骨垫片更换可获得较持久的生存率。
  • 对于不稳定、垫片骨折/脱位或僵硬,应预期更高再翻修风险,需谨慎选择并告知患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA). METHODS: From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded. RESULTS: Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years. CONCLUSION: After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103-1110.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Tetreault MW, Hines JT, Berry DJ, et al. Isolated tibial insert exchange in revision total knee arthroplasty : reliable and durable for wear; less so for instability, insert fracture/dissociation, or stiffness. Bone Joint J. 2021. PMID: 34058882. doi:10.1302/0301-620X.103B6.BJJ-2020-1954.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。