生物复合堆叠螺钉在单期翻修前交叉韧带重建中固定强度可接受:猪尸体模型
本研究在猪尸体模型上比较两种生物复合堆叠螺钉构造与初次前交叉韧带重建的固定强度,30条猪腿分三组进行生物力学测试。结果显示两种翻修构造的拔出力与初次重建无显著差异,其中一种构造线性刚度显著更高,提示堆叠螺钉在骨缺损单期翻修中可提供足够固定强度。
要点
- 两种堆叠螺钉翻修构造拔出力与初次重建无显著差异。
- 组2线性刚度显著高于初次重建组。
- 骨缺损单期翻修可采用堆叠螺钉构造提供足够固定。
核心结论
- 在猪模型中,两种生物复合堆叠螺钉构造用于骨缺损单期翻修前交叉韧带重建,其固定强度和线性刚度与初次重建相似。
研究设计与样本
- 控制实验室研究,共30条猪腿分为3组,组1为初次重建,组2和组3为翻修堆叠螺钉构造。
主要发现
- 组1、2、3平均拔出力分别为626±145 N、653±152 N、720±125 N(P=.328)。
- 组1、2、3平均线性刚度分别为71.4±9.9 N/mm、84.1±11.1 N/mm、82.0±10.8 N/mm。
- 组2线性刚度显著高于组1(P=.037)。
关键数值与推荐
- 初次重建使用8 mm生物复合干涉螺钉固定髌腱移植物于股骨。
- 翻修模型先用12 mm生物复合螺钉填充骨隧道,再钻新隧道并插入髌骨骨塞。
- 组2在移植物对侧用8 mm生物复合螺钉固定,组3将干涉螺钉置于移植物与填充螺钉之间。
- 以1.5 mm/s速度沿隧道方向加载至失败,记录失败载荷、线性刚度和失败模式。
临床怎么用
- 在隧道位置不良导致骨缺损时,单期翻修前交叉韧带重建使用堆叠螺钉构造可能提供足够的固定强度和线性刚度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Stacked screws is a commonly used technique in single-stage revision anterior cruciate ligament (ACL) reconstruction in the setting of bone loss, but there are limited data to support its use. HYPOTHESIS: Two configurations of a biocomposite stacked screws construct have similar fixation strength and linear stiffness as a primary ACL reconstruction construct in a biomechanical model. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 30 porcine legs were divided into 3 groups. Group 1 underwent primary ACL reconstruction with a patellar tendon graft fixed into the femur, with an 8-mm biocomposite interference screw of beta-tricalcium phosphate and poly lactide-co-glycolide. For a revision ACL reconstruction model, groups 2 and 3 had bone tunnels created and subsequently filled with 12-mm biocomposite screws. New bone tunnels were drilled through the filler screw and the surrounding bone, and the patellar bone plug was inserted. Group 2 was fixed with 8-mm biocomposite screws on the side of the graft opposite the filler screw, while group 3 had the interference screw interposed between the graft and the filler screw. The construct was loaded at 1.5 mm/s in line with the tunnel until failure. Load to failure, linear stiffness, and mode of failure were recorded. RESULTS: The mean pullout strength for groups 1, 2, and 3 was 626 ± 145 N, 653 ± 152 N, and 720 ± 125 N, respectively (P = .328). The mean linear stiffness of the construct in groups 1, 2, and 3 was 71.4 ± 9.9 N/mm, 84.1 ± 11.1 N/mm, and 82.0 ± 10.8 N/mm, respectively. Group 2 was significantly stiffer than group 1 (P = .037). CONCLUSION: Two configurations of a biocomposite stacked screws construct for a single-stage revision ACL reconstruction in the setting of bone loss show a similar fixation strength and linear stiffness to a primary ACL reconstruction at time zero in a porcine model. CLINICAL RELEVANCE: In the setting of bone loss from tunnel malpositioning, a single-stage revision ACL reconstruction using a stacked screws construct may provide adequate fixation strength and linear stiffness.
引用
- Baydoun H, Engler ID, Hosseini A, et al. Stacked Biocomposite Screws in a Single-Stage Revision Anterior Cruciate Ligament Reconstruction Has Acceptable Fixation Strength in a Porcine Cadaveric Model. Am J Sports Med. 2021. PMID: 34048276. doi:10.1177/03635465211015192
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。