解剖型全肩关节置换术后五年肱骨适应性放射学改变
本研究纳入44例使用标准长度非骨水泥羟基磷灰石涂层肱骨假体的解剖型全肩关节置换术,通过三名观察者评估术后六年与五年的X线骨适应性改变,并用软件校正灰度值客观分析假体周围骨密度。结果显示应力遮挡轻度14肩、中度3肩,结节间沟为主要部位;无应力遮挡者1区和7区灰度值平均下降20%,有应力遮挡者下降38%。
要点
- 标准长度非骨水泥HA涂层肱骨假体五年中度应力遮挡率为7%。
- 大结节是应力遮挡主要发生部位。
- X线可见应力遮挡对应灰度值下降约25%或以上。
核心结论
- 植入非骨水泥标准长度HA涂层肱骨假体五年后,中度应力遮挡率为7%。
- X线观察到的应力遮挡似乎代表灰度值下降25%或以上。
研究设计与样本
- 回顾性纳入2011至2014年间44例解剖型全肩关节置换术,使用近端HA涂层的非骨水泥标准长度肱骨假体。
- 23例男性、21例女性,平均年龄65岁(17至65岁)。
- 所有肩关节均有术后六周和五年质量良好的X线片。
- 三名观察者对骨适应性改变进行分级。
- 将所有X线片上传至商用摄影软件,将肱骨放射区域灰度值密度校正至肱骨假体灰度值密度并进行时间比较。
主要发现
- 应力遮挡轻度14肩、中度3肩,大结节为主要部位。
- 干骺端和骨干填充匹配比均值分别为0.56(SD 0.1)和0.5(SD 0.07)。
- 无放射学可见应力遮挡的肩关节中,1区和7区灰度值平均下降20%,而有放射学可见应力遮挡的肩关节下降38%。
关键数值与推荐
- 中度应力遮挡率为7%(3/44)。
- 无应力遮挡者1区和7区灰度值平均下降20%,有应力遮挡者下降38%。
- X线可见应力遮挡对应灰度值下降25%或以上。
临床怎么用
- 术后五年随访时应关注大结节区域的应力遮挡征象。
- 可借助软件校正灰度值客观评估假体周围骨密度变化。
- X线可见应力遮挡可能提示灰度值下降25%或以上,需结合临床判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively. METHODS: A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time. RESULTS: Stress shielding was graded as mild in 14 shoulders and moderate in three; the greater tuberosity was the predominant site for stress shielding. The mean metaphyseal and diaphyseal fill-fit ratios were 0.56 (SD 0.1) and 0.5 (SD 0.07), respectively. For shoulders with no radiologically visible stress shielding, the mean decrease in grey value in zones 1 and 7 was 20%, compared with 38% in shoulders with radiologically visible stress shielding. CONCLUSION: The rate of moderate stress shielding was 7%, five years after implantation of a cementless standard-length HA-coated humeral component. Clinical observation of stress shielding identified on radiographs seems to represent a decrease in grey value of 25% or more. Cite this article: Bone Joint J 2021;103-B(5):958-963.
引用
- Nguyen NTV, Martinez-Catalan N, Songy CE, et al. Radiological humeral adaptative changes five years after anatomical total shoulder arthroplasty using a standard-length cementless hydroxyapatite-coated humeral component. Bone Joint J. 2021. PMID: 33934651. doi:10.1302/0301-620X.103B5.BJJ-2020-1619.R1