PubMed 文献 · J Bone Joint Surg Am · 2021-01-01

球面髋臼周围截骨术(SPO)是一种新型截骨术,通过劈开泪滴并使用患者特异性术前规划,仅需7cm皮肤切口。研究回顾性分析52例(55髋)髋关节发育不良患者,随访至少2年,结果显示影像学参数显著改善,但20%髋出现矫正丢失,无患者需转为全髋关节置换。

要点

  • SPO通过术前三维模板规划,将弧形骨刀半径映射穿过泪滴、坐骨髋臼下沟及髂前上棘与髂前下棘之间区域。
  • 术后外侧中心边缘角和眉弓角显著改善(p<0.001),但20%髋出现矫正丢失(骨旋转<3mm或眉弓角<3°)。
  • 所有髋在3个月内骨愈合,无患者需转为全髋关节置换,临床评分2年随访显著改善。

核心结论

  • SPO是一种新型微创髋臼周围截骨术,潜在缺点是早期矫正丢失(本研究中20%髋出现),但可能降低耻骨截骨部位不愈合风险。

研究设计与样本

  • 回顾性分析52例连续患者(55髋)髋关节发育不良,接受SPO并随访至少2年;术前CT导入三维模板软件规划截骨。

主要发现

  • 术前外侧中心边缘角平均6.0°(范围-20°至18°),术后30.0°(15°至43°);术前眉弓角平均26.0°(13°至38°),术后3.8°(-4°至27°)(p<0.001)。
  • 11髋(20%)出现骨旋转矫正丢失(<3mm)或眉弓角矫正丢失(<3°)。
  • 所有髋在术后3个月内X线显示骨愈合;2髋因可吸收螺钉行早期二次手术。
  • 2年随访临床评分显著改善(p<0.001);股外侧皮神经区感觉异常常见,但92%患者在2年随访时缓解。

关键数值与推荐

  • 截骨高度和预测骨刀插入深度在术前测量并在术中重现。
  • 旋转骨块和髂嵴用可吸收螺钉固定。
  • Tönnis分级:0级27髋,1级21髋,2级7髋;手术时平均年龄38岁(范围17至56岁)。

临床怎么用

  • SPO可作为髋关节发育不良的微创治疗选择,需注意早期矫正丢失风险,术后需密切影像学随访。

局限性

  • 回顾性研究,证据等级为治疗性IV级;短期随访至少2年;样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Spherical periacetabular osteotomy (SPO) is a novel osteotomy involving splitting the teardrop, using patient-specific preoperative planning, and requiring only a 7-cm skin incision. We report preoperative planning methods and short-term results of SPO. METHODS: In preoperative planning, computed tomography (CT) images were imported into 3-dimensional templating software. The radius of the curved chisel was mapped to pass through the teardrop, the infracotyloid groove of the ischium, and the area between the anterior superior iliac spine and the anterior inferior iliac spine. The osteotomy height and the predicted depth of osteotome insertion were measured, and those values were reproduced during surgery. We performed a retrospective analysis of data on 52 consecutive patients (55 hips) with hip dysplasia who underwent SPO and were followed for at least 2 years: 27 hips had Tönnis grade 0, 21 had grade 1, and 7 had grade 2. The mean age at surgery was 38 years (range, 17 to 56 years). The rotated bone fragment and iliac crest were fixed with absorbable screws. Statistical analysis was performed with the paired t test. RESULTS: The mean (range) of the lateral center-edge and sourcil angles were 6.0° (-20° to 18°) and 26.0 (13° to 38°), respectively, before surgery and 30.0° (15° to 43°) and 3.8° (-4° to 27°), respectively, after surgery (p < 0.001). However, 11 hips (20%) showed a loss of correction of bone rotation (<3 mm) or the sourcil angle (<3°). Radiographs showed bone union in all hips within 3 months after the surgery. Early second surgery related to absorbable screws was performed in 2 hips. No patient had required conversion to total hip arthroplasty at the time of writing. Clinical scores were significantly improved at the 2-year follow-up (p < 0.001). Paresthesia of the lateral femoral cutaneous nerve area was very common but had resolved in 92% of the patients at the 2-year follow-up. CONCLUSIONS: SPO is a novel minimally invasive periacetabular osteotomy that has the potential disadvantage of early loss of correction (observed in 20% of the hips in the present study) but may provide the benefit of decreasing the risk of nonunion at the pubis osteotomy site. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.