文献速递关节外科

术后屈曲角度良好可改善膝关节功能,屈曲角度改善可提高全膝关节置换术后患者满意度

Good Postoperative Flexion Angle Improves Knee Function and Improvement of Flexion Angle Increases Patient Satisfaction After Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2021-05-05

该回顾性研究纳入375例患者共500例初次全膝关节置换术(TKA),评估术后活动度(ROM)与患者报告结局(PROM)及满意度之间的关系。结果显示术后屈曲角度对膝关节功能有显著影响(P < .001),获得良好功能的屈曲角度截断值为120°;屈曲角度改善对患者满意度有显著影响(P = .004),改善的截断值为5°。

要点

  • 术后屈曲角度对膝关节功能有显著影响(P < .001),良好功能截断值为120°。
  • 屈曲角度改善对患者满意度有显著影响(P = .004),改善截断值为5°。
  • TKA术后应关注屈曲角度的恢复与改善,以优化功能和满意度。

核心结论

  • 术后屈曲角度对膝关节功能有显著影响,屈曲角度改善对患者满意度有显著影响。

研究设计与样本

  • 回顾性研究,纳入375例患者共500例初次全膝关节置换术(TKA),测量术前术后活动度(ROM),采用膝关节损伤和骨关节炎结局评分(KOOS)评估功能,5级量表评估满意度,并运用多元逻辑回归和ROC曲线分析。

主要发现

  • 术后屈曲角度对膝关节功能有显著影响(P < .001)。
  • 屈曲角度改善对患者满意度有显著影响(P = .004)。

关键数值与推荐

  • 获得良好膝关节功能的术后屈曲角度截断值为120°。
  • 屈曲角度改善的截断值为5°。

临床怎么用

  • TKA术后应重视屈曲角度的恢复,争取达到120°以获良好功能,并关注屈曲角度改善至少5°以提高满意度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total knee arthroplasty (TKA) is a well-established procedure for treating knee joint diseases. However, the postoperative range of motion (ROM) varies and is an important indicator of TKA success. Recently, patient-reported outcome measures (PROMs) and patient satisfaction have drawn attention. However, the relationship between ROM and knee function obtained by PROM and satisfaction is not well understood. METHODS: We retrospectively reviewed the data of 375 patients who underwent 500 primary TKA procedures. We measured the ROM before and after surgery. Knee joint function was evaluated using the Knee Injury Osteoarthritis Outcome Score, a PROM, and patients were classified into good function and poor function groups. Patient satisfaction was evaluated on a 5-graded scale as overall satisfaction, and patients were divided into a satisfied or a dissatisfied group according to the obtained scores. ROM was compared between the 2 groups, then significantly different factors were analyzed using multiple logistic regression analysis. Moreover, cut-off points of ROM for obtaining good function and patient satisfaction were determined using ROC curve analysis. RESULTS: The postoperative flexion angle had a significant effect on knee function (P < .001). The cut-off value of the postoperative flexion angle for good knee function was 120°. The improvement in flexion angle had a significant effect on patient satisfaction (P = .004). The cut-off value for the improvement in the flexion angle was 5°. CONCLUSION: The postoperative flexion angle had a significant effect on knee function and improvement in the flexion angle had a significant effect on patient satisfaction.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kubo M, Maeda T, Kumagai K, et al. Good Postoperative Flexion Angle Improves Knee Function and Improvement of Flexion Angle Increases Patient Satisfaction After Total Knee Arthroplasty. J Arthroplasty. 2021. PMID: 34034923. doi:10.1016/j.arth.2021.04.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。