约束性髋臼内衬在初次与翻修全髋关节置换术中的生存率与临床结局:系统综述
该系统综述纳入37篇文献、共4152个约束性髋臼内衬(CAL),评估其在复杂初次及翻修全髋关节置换术中的生存率与并发症。全因免再手术生存率为79.9%,总体并发症率22.2%,脱位是最常见并发症(9.4%)和再手术原因(9.2%)。结论认为CAL并发症率较高,但在反复脱位和假体不稳的复杂患者中仍是有价值的挽救性手段,且需在明确并优化不稳原因后使用。
要点
- CAL全因免再手术生存率79.9%,总体并发症率22.2%。
- 脱位是最常见并发症(9.4%)和再手术原因(9.2%)。
- CAL应仅在不稳原因被正确识别并优化后使用。
核心结论
- CAL并发症率相对较高,尤其与双动杯和大直径股骨头等现行替代方案相比。
- CAL在反复脱位和假体不稳的复杂患者中仍是有价值的挽救性手术。
- 新设计显示撞击减少且免脱位生存率更高,但CAL应仅在正确识别并优化不稳原因后使用。
研究设计与样本
- 遵循PRISMA指南的系统综述。
- 检索PubMed、MEDLINE、EMBASE和Cochrane系统综述数据库的英文文献。
- 共37篇文章符合纳入标准,累计植入4152个CAL。
主要发现
- 全因免再手术生存率为79.9%。
- 总体并发症率为22.2%。
- 脱位是最常见并发症,发生率为9.4%,也是最常见再手术原因,发生率为9.2%。
- CAL置入后感染发生率为4.6%。
- 无菌性髋臼组件松动再手术率为2.9%。
临床怎么用
- CAL可用于反复脱位和假体不稳的复杂初次或翻修全髋关节置换患者。
- 使用CAL前必须正确识别并优化不稳原因。
- 需向患者告知CAL并发症率较高,尤其与双动杯和大直径股骨头相比。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Several studies have evaluated the survivorship and clinical outcomes of constrained acetabular liners (CALs) in complex primary and revision total hip arthroplasty with hip instability; however, there remains no consensus on the overall performance of this constrained implant. We therefore performed a systematic review of the literature to examine survivorship and complication rate of CAL usage. METHODS: A systematic review of the literature in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. A comprehensive search of PubMed, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was conducted for English articles using various combinations of keywords. RESULTS: In all, 37 articles met the inclusion criteria. A total of 4152 CALs were implanted. The all-cause reoperation-free survivorship was 79.9%. The overall complication rate was 22.2%. Dislocation was the most common complications observed and the most frequent reason for reoperation with an incidence of 9.4% and 9.2%, respectively. Infection after CAL placement had an incidence of 4.6%. The reoperation rate for aseptic acetabular component loosening was 2.9%. Overall, patients had improved outcomes as documented by postoperative hip scores. CONCLUSION: CALs usage have a relatively high complication rate, particularly when compared with current bearing alternatives (dual mobility cups and large diameter femoral heads), however, it remains a valuable salvage procedure in complex patients affected by recurrent dislocation and implant instability. Newer designs have shown reduced impingement and higher survivorship free from dislocation. However, CALs should only be used when the reasons of instability have been correctly recognized and optimized.
引用
- Mancino F, Jones CW, Sculco TP, et al. Survivorship and Clinical Outcomes of Constrained Acetabular Liners in Primary and Revision Total Hip Arthroplasty: A Systematic Review. J Arthroplasty. 2021. PMID: 34030877. doi:10.1016/j.arth.2021.04.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。