文献速递关节外科运动医学

高交联聚乙烯可降低高需求患者全髋关节置换术的磨损率:配对对照研究

Highly Crosslinked Polyethylene Can Reduce Wear Rate in THA for High-Demand Patients: A Matched-Paired Controlled Study.
PubMed 文献 · J Arthroplasty · 2021-05-03

HXLPE组线性磨损率显著低于cPE组,骨溶解发生率更低,功能结果相似。

要点

  • 高需求患者中,HXLPE组线性磨损率显著低于cPE组(P<.0001)。
  • cPE组有3例假体周围骨溶解,HXLPE组无骨溶解病例。
  • 两组功能评分改善相当,HXLPE组部分生活质量评分更高但差异未超最小临床重要差异。

核心结论

  • 参与冲击性运动并接受陶瓷对HXLPE全髋关节置换术的患者,其磨损和骨溶解率低于接受陶瓷对cPE者,功能结果相似。

主要发现

  • cPE组线性磨损率为0.13503±0.0630 mm/年,HXLPE组为0.03059±0.0084 mm/年,差异有统计学意义(P<.0001)。
  • 全队列Harris髋关节评分术后增加37.64,两组相当(P=.3674)。
  • HXLPE组髋关节和骨关节炎 outcome 评分在疼痛(P=.0009)、日常生活活动(P=.0016)和生活质量(P=.0179)方面显著更高,但组间差异低于报道的最小临床重要差异。
  • cPE组3例出现假体周围骨溶解迹象(股骨侧1例,髋臼侧2例),HXLPE组无。
  • 两组均无因无菌性松动而翻修的病例。

临床怎么用

  • 对于常进行冲击性运动的高需求全髋关节置换术患者,选用陶瓷对HXLPE可能降低磨损和骨溶解风险,且功能结果与cPE相似。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The average age of patients benefiting from total hip arthroplasty (THA) has been declining. In addition to pain relief, patients seek to return to physical activity. However, the latter may increase polyethylene wear and therefore the potential risk of early aseptic loosening. The introduction of highly crosslinked polyethylene (HXLPE) has reduced wear rates in the general patient population. The objective of this study was to evaluate the influence of impact sports in patients operated with THA using ceramic-on-conventional polyethylene (cPE) versus ceramic-on-HXLPE, in terms of wear and function, with a minimum of five year follow-up. METHODS: Sixty-eight patients practicing an impact sport (University of California Los Angeles score ≥8) who underwent a primary THA were included: 34 with a ceramic-on-cPE versus 34 with a ceramic-on-HXLPE using the same cementless acetabular and femoral component. Patients were matched-paired by age, sex, BMI, and University of California Los Angeles score. The wear analysis was performed using the IMAGIKA software. The Harris hip score and hip and osteoarthritis outcome score were collected. RESULTS: The linear wear rate was statistically higher (P < .0001) in the cPE group (0.13503 ± 0.0630 mm/year) than in the HXLPE group (0.03059 ± 0.0084 mm/year). Postoperatively, the increase in Harris hip score was calculated at 37.64 for the entire cohort and was comparable in both groups (P = .3674). The hip and osteoarthritis outcome score for pain (P = .0009), daily life activities (P = .0016), and quality of life (P = .0179) were significantly higher in the HXLPE group, with, between groups, a difference inferior to the reported minimal clinical important difference. Three patients exhibited signs of periprosthetic osteolysis in the cPE group, one on the femoral side and two on the acetabular side. None were observed in the HXLPE group. No revision for aseptic loosening was reported in both cohorts. CONCLUSION: Patients partaking in impact sports and receiving a ceramic-on-HXLPE THA demonstrated lower wear and osteolysis rates than those having a ceramic-on-cPE THA, with similar functional results.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Guy S, Flecher X, Sharma A, et al. Highly Crosslinked Polyethylene Can Reduce Wear Rate in THA for High-Demand Patients: A Matched-Paired Controlled Study. J Arthroplasty. 2021. PMID: 34024694. doi:10.1016/j.arth.2021.04.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。