假体周围关节感染诊断中mNGS标本类型选择

Better choice of the type of specimen used for untargeted metagenomic sequencing in the diagnosis of periprosthetic joint infections.
PubMed 文献 · Bone Joint J · 2021-01-01

该前瞻性研究纳入59例翻修关节置换的177份标本,比较假体周围组织、滑液和假体超声液三种标本的mNGS诊断价值。mNGS总体灵敏度95%、特异度94.7%,其中假体超声液灵敏度92.5%、病原体检出率84.6%最优,建议可部分替代传统培养。

要点

  • mNGS诊断PJI总体灵敏度95%、特异度94.7%。
  • 假体超声液mNGS灵敏度92.5%,病原体检出率84.6%最优。
  • 假体超声液mNGS可部分替代传统细菌培养。

核心结论

  • mNGS使用三种标本均可准确检测PJI患者病原体。
  • 假体超声液mNGS因病原体识别性能更优而最具价值,可能部分替代细菌培养等传统检测。

研究设计与样本

  • 前瞻性研究,收集59例翻修关节置换的177份标本,包括假体周围组织、滑液和假体超声液。
  • 每份标本分为两份,分别用于mNGS和培养。
  • 采用肌肉骨骼感染学会标准定义PJI(40例)和无菌性失败(19例)。

主要发现

  • mNGS诊断PJI的总体灵敏度95%、特异度94.7%。
  • 假体周围组织mNGS灵敏度65%、特异度100%。
  • 滑液mNGS灵敏度87.5%、特异度94.7%。
  • 假体超声液mNGS灵敏度92.5%、特异度94.7%。
  • 假体超声液mNGS在病原体检出率(84.6%)、测序读数(>十倍)和基因组覆盖度(>五倍)方面优于其他标本。

关键数值与推荐

  • 采用肌肉骨骼感染学会标准定义PJI(40例)和无菌性失败(19例)。

临床怎么用

  • 在PJI诊断中可选用假体超声液进行mNGS检测,以提高病原体检出。
  • 假体超声液mNGS可能部分替代传统细菌培养。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: As a proven and comprehensive molecular technique, metagenomic next-generation sequencing (mNGS) has shown its potential in the diagnosis of pathogens in patients with periprosthetic joint infection (PJI), using a single type of specimen. However, the optimal use of mNGS in the management of PJI has not been explored. In this study, we evaluated the diagnostic value of mNGS using three types of specimen with the aim of achieving a better choice of specimen for mNGS in these patients. METHODS: In this prospective study, 177 specimens were collected from 59 revision arthroplasties, including periprosthetic tissues, synovial fluid, and prosthetic sonicate fluid. Each specimen was divided into two, one for mNGS and one for culture. The criteria of the Musculoskeletal Infection Society were used to define PJI (40 cases) and aseptic failure (19 cases). RESULTS: The sensitivity and specificity of mNGS in the diagnosis of PJI were 95% and 94.7%, respectively, for all types of specimen. The sensitivity and specificity were 65% and 100%, respectively, for periprosthetic tissues, 87.5% and 94.7%, respectively, for synovial fluid, and 92.5% and 94.7%, respectively, for prosthetic sonicate fluid. The mNGS of prosthetic sonicate fluid outperformed that for other types of specimen in the rates of detection of pathogens (84.6%), sequencing reads (> ten-fold) and the rate of genome coverage (> five-fold). CONCLUSION: mNGS could serve as an accurate diagnostic tool in the detection of pathogens in patients with a PJI using three types of specimen. Due to its superior perfomance in identifying a pathogen, mNGS of prosthetic sonicate fluid provides the most value and may partly replace traditional tests such as bacteriological culture in these patients. Cite this article: Bone Joint J 2021;103-B(5):923-930.