滑液金属离子水平预测全髋关节置换失败后不良局部组织反应优于血液
本研究在翻修全髋关节置换术中采集滑液和血液,比较有和无不良局部组织反应(ALTR)患者的金属离子浓度。结果显示ALTR患者滑液钴浓度为血液的120倍,铬为414倍,滑液钴浓度预测ALTR最准确(截断值19.75 ppb,AUC 0.973)。
要点
- ALTR患者滑液钴浓度是血液的120倍,铬是414倍。
- 滑液钴浓度预测ALTR的截断值为19.75 ppb,AUC 0.973。
- 滑液钴浓度是检测ALTR最准确的指标。
核心结论
- ALTR患者滑液钴和铬浓度分别比全血高120倍和414倍。
- 滑液钴离子浓度预测ALTR最准确。
研究设计与样本
- 在翻修全髋关节置换术中采集滑液和血液样本,ALTR组26例,无ALTR组27例。
- 诊断证据级别为II级。
主要发现
- 滑液钴浓度检测ALTR的截断值为19.75 ppb,AUC为0.973。
关键数值与推荐
- 滑液钴浓度截断值19.75 ppb,AUC 0.973。
临床怎么用
- 在翻修全髋关节置换术前,可考虑检测滑液金属离子浓度以辅助预测ALTR。
- 滑液钴浓度可能比血液钴浓度更准确地预测ALTR。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Adverse local tissue reactions (ALTR) are associated with total hip arthroplasty (THA) failure in patients with metal-on-metal bearings and/or taper corrosion, which can also occur in metal-on-polyethylene articulations. Patients are monitored with blood cobalt (Co) and chromium (Cr) concentrations which do not always correlate with the degree of soft tissue reaction at revision THA. The purpose of this study was to determine how the blood and prosthetic hip synovial fluid levels of Co and Cr correlate with one another, and determine which concentration is more predictive of ALTR. METHODS: Synovial fluid and blood samples were collected at the time of revision THA in patients with (n = 26) and without ALTR (n = 27). Whole blood, serum, and synovial fluid metal ion concentrations were correlated with one another and clinical findings. RESULTS: The ratio of synovial fluid to whole blood Co concentration in ALTR and non-ALTR hips was 120:1 and 18:1 (P = .006). The mean ratio of synovial fluid to whole blood Cr concentration in ALTR and non-ALTR hips was 414:1 and 24:1 (P = .01). The mean synovial fluid Co/Cr concentrations were elevated in patients with ALTR compared with those without (2007.3 vs. 12.4 ppb, P = .007) and (3188.2 vs. 10.3 ppb, P = .02). The synovial fluid Co concentration was the most accurate test for detecting ALTR (cut off: 19.75 PPB, AUC 0.973). CONCLUSION: In patients with ALTR, synovial fluid Co and Cr levels were 120 times higher and 414 times higher than whole blood Co and Cr levels. Synovial fluid Co ion concentration was the most accurate in predicting ALTR. LEVEL OF EVIDENCE: Diagnostic level II.
引用
- Houdek MT, Taunton MJ, Wyles CC, et al. Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty. J Arthroplasty. 2021. PMID: 34030874. doi:10.1016/j.arth.2021.04.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。