ProDisc-C Vivo单节段颈椎人工椎间盘置换五年随访结果
回顾性研究评估28例单节段ProDisc-C Vivo颈椎置换患者五年随访,手术节段活动度维持,50%出现异位骨化但仅14.3%为重度,脊髓型与神经根型患者临床评分显著改善,无再手术。
要点
- 手术节段活动度五年维持(8.9°±2.3°至8.3°±4.8°,P=0.494)
- 异位骨化发生率50%,重度(McAfee III-IV级)仅14.3%
- 脊髓型mJOA与神经根型VAS均显著改善,无再手术
核心结论
- ProDisc-C Vivo单节段颈椎置换五年临床与影像学结果满意。
研究设计与样本
- 回顾性研究,纳入28例单节段ProDisc-C Vivo置换患者,平均随访65个月。
主要发现
- 手术节段活动度基线8.9°±2.3°,末次随访8.3°±4.8°(P=0.494)。
- 28节段中14节(50%)出现异位骨化,McAfee I级1节、II级9节、III级2节、IV级2节,重度仅4节(14.3%)。
- 脊髓型患者mJOA基线13.9±2.5,末次随访15.9±1.0(P=0.001)。
- 神经根型患者VAS颈肩基线5.4±1.4,末次随访0.7±1.2(P=0.000);VAS臂基线5.1±2.8,末次随访0.5±1.2(P=0.000)。
- 49个邻近节段中13个(26.5%)出现退变,无因邻近节段病复发神经根病或脊髓病,无再手术。
临床怎么用
- 单节段颈椎置换五年可维持活动度并改善脊髓型与神经根型症状。
- 需关注异位骨化发生,但重度比例较低且无再手术。
局限性
- 回顾性研究,证据等级为4级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective study. OBJECTIVE: The aim of this study was to evaluate the long-term clinical and radiographic outcomes of cervical arthroplasty using the ProDisc-C Vivo prosthesis. SUMMARY OF BACKGROUND DATA: Previous reports have shown that cervical arthroplasty with ProDisc-C artificial disc has acceptable clinical outcomes at 5-year and 10-year follow-ups. METHODS: Clinical and radiographic evaluations, including dynamic flexion-extension lateral images, were performed at baseline and at the 5-year follow-up. RESULTS: Twenty-eight patients who underwent single-level ProDisc-C Vivo arthroplasty were followed-up for a mean period of 65 months. The range of motion at the operated level was 8.9° ± 2.3° at baseline and 8.3° ± 4.8° at the final follow-up (P = 0.494). Fourteen of 28 levels (50%) developed heterotopic ossification (HO). According to McAfee's classification, one level was classified as grade I, nine levels as grade II, two levels as grade III, and two levels as grade IV. Only four of 28 levels (14.3%) had severe HO. Among patients with cervical spondylotic myelopathy, mJOA score was 13.9 ± 2.5° at baseline and 15.9° ± 1.0° at the final follow-up (P = 0.001 < 0.05). Among patients with cervical spondylotic radiculopathy, Visual Analog Scale (VAS) neck and shoulder was 5.4 ± 1.4° at baseline and 0.7° ± 1.2° at the final follow-up (p = 0.000 < 0.05), VAS arm was 5.1 ± 2.8° at baseline and 0.5° ± 1.2° at the final follow-up (P = 0.000 < 0.05). A total of 49 adjacent segments were observed and 13 (26.5%) had adjacent segment degeneration. No patient developed recurrent cervical radiculopathy or myelopathy due to adjacent segment disease. No patient underwent re-operation. CONCLUSION: ProDisc-C Vivo arthroplasty had satisfactory clinical and radiographic outcomes at 5-year follow-up.Level of Evidence: 4.
引用
- Cao S, Zhao Y, Sun Y, et al. Single-level Cervical Arthroplasty with Prodisc-C Vivo Artificial Disc: Five-year Follow-up Results From One Center. Spine (Phila Pa 1976). 2022. PMID: 33988531. doi:10.1097/BRS.0000000000004119
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。