文献速递骨肿瘤关节外科

干骺端柄尖位置是骨水泥型股骨远端置换无菌性松动的危险因素

Metaphyseal Stem Tip Location is a Risk Factor for Aseptic Loosening of Cemented Distal Femoral Replacements.
PubMed 文献 · J Arthroplasty · 2021-05-05

本研究回顾性分析了40年间单中心245例初次骨水泥柄股骨远端置换,无菌性松动发生率为11.8%(29/245)。多因素分析显示年轻年龄、男性、较长切除长度及非模块化假体与无菌性松动显著相关;

要点

  • 骨水泥柄股骨远端置换无菌性松动发生率为11.8%。
  • 年轻、男性、长切除、非模块化假体与无菌性松动相关。

核心结论

  • 柄尖位于干骺端骨内与无菌性松动生存率降低相关。
  • 术前模板测量柄尖位置有助于识别高风险重建,可能受益于替代或辅助固定技术。

研究设计与样本

  • 回顾性综述了40年期间单中心连续245例初次骨水泥柄股骨远端置换。
  • 主要结局为因无菌性松动行翻修手术,采用多因素分析识别危险因素。

主要发现

  • 无菌性松动和结构失败是最常见假体失败原因,发生率为11.8%(29/245)。
  • 松动的25例假体中36%(9/25)柄尖位于干骺端,而未失败的25例中仅8%(2/25)。

临床怎么用

  • 在股骨远端置换术前模板测量时,应评估柄尖位置以识别无菌性松动高风险重建。
  • 对于柄尖可能位于干骺端的高风险病例,可考虑替代或辅助固定技术以预防无菌性松动。

局限性

  • 本研究为单中心回顾性设计,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objective of this study was to describe the incidence of aseptic loosening (AL) of cemented stem distal femoral replacements (DFR) and to identify modifiable risk factors for its development. METHODS: A retrospective review was performed of 245 consecutive primary, cemented stem DFRs implanted at a single institution over a 40-year period. The primary outcome was revision surgery for AL. A multivariate analysis was performed to identify risk factors for AL. Radiographs were reviewed to identify stem tip location, which was defined as diaphyseal or metaphyseal. Implant survival to AL was compared using Kaplan-Meier analysis. RESULTS: AL and structural failure were the most common causes of implant failure (incidence 11.8%, 29/245). Younger age (P = .002), male sex (P = .01), longer resection length (P = .04), and nonmodular implants (P = .002) were all significantly associated with AL. After 1:1 matching, stem tip location in metaphyseal bone was independently associated with AL (P = .04). 36% (9/25) of implants that loosened had a stem tip located in the metaphysis vs only 8% (2/25) of implants that did not fail. 30-year survival to AL was lower for implants with a metaphyseal stem tip than implants with a diaphyseal stem tip (22.7% vs 47.6%; P = .11). CONCLUSION: A stem tip location in metaphyseal bone is associated with diminished survival to AL. When templating before DFR, stem tip location can assist in identifying high-risk reconstructions that may benefit from alternative or supplemental fixation techniques to prevent the development of AL.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Greig D, Trikha R, Geiger EJ, et al. Metaphyseal Stem Tip Location is a Risk Factor for Aseptic Loosening of Cemented Distal Femoral Replacements. J Arthroplasty. 2021. PMID: 34030876. doi:10.1016/j.arth.2021.04.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。