文献速递脊柱外科创伤骨科

动力辅助椎弓根螺钉技术可降低术者过度使用损伤风险:模拟手术环境下颈部与上肢肌群的肌电对比研究

Power-assisted Pedicle Screw Technique Protects Against Risk of Surgeon Overuse Injury: A Comparative Electromyography Study of the Neck and Upper Extremity Muscle Groups in a Simulated Surgical Environment.
PubMed 文献 · Spine (Phila Pa 1976) · 2022-01-01

该尸体研究在模拟手术环境中用表面肌电比较徒手与动力辅助工具从椎弓根穿刺到螺钉置入过程中术者肌群用力情况。动力辅助工具使所有肌群平均用力维持在过度使用损伤低风险水平,而徒手技术下部分肌群在50%至92%手术时间内处于损伤风险水平。

要点

  • 动力辅助工具使所有肌群平均用力处于过度使用损伤低风险水平。
  • 徒手技术下伸腕桡肌、肱二头肌、上斜方肌和颈伸肌在50%至92%手术时间处于风险水平。
  • 动力辅助工具使肱二头肌、肱三头肌和三角肌平均用力降低达80%以上。

核心结论

  • 动力辅助技术可保护术者免受过度使用损伤风险。
  • 徒手技术下伸腕桡肌、肱二头肌、上斜方肌和颈伸肌的用力升高与术者自我报告的肱骨外上髁炎、肩袖疾病和颈椎病诊断直接相关。

研究设计与样本

  • 尸体研究,由两名委员会认证脊柱外科医生在四具尸体上从T4至L5使用徒手与动力辅助两种技术完成椎弓根准备和螺钉置入。
  • 使用表面肌电记录伸腕桡肌、伸腕桡侧肌、肱二头肌、肱三头肌、三角肌、上斜方肌和颈伸肌的肌肉活动。
  • 肌肉活动以各肌群最大自主用力的百分比(%MVE)报告,并依据文献将用力分为低(0-20% MVE)、中(20%-45% MVE)、高(45%-70% MVE)和最高(70%-100% MVE)过度使用损伤风险。

主要发现

  • 动力辅助工具用于椎弓根穿刺至螺钉置入时,每个肌群的平均肌肉用力均维持在过度使用损伤低风险水平。
  • 徒手技术下,伸腕桡肌、肱二头肌、上斜方肌和颈伸肌在50%至92%的手术时间内处于有过度使用损伤风险的用力水平。
  • 动力辅助工具使肱二头肌、肱三头肌和三角肌的平均肌肉用力降低达80%以上。

临床怎么用

  • 在开放后路固定手术中,从椎弓根穿刺到螺钉置入使用动力辅助工具有助于降低术者上肢和颈部肌群的用力及过度使用损伤风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Cadaveric. OBJECTIVE: The aim of this study was to quantify the amplitude and duration of surgeons' muscle exertion from pedicle cannulation to screw placement using both manual and power-assisted tools in a simulated surgical environment using surface electromyography (EMG). SUMMARY OF BACKGROUND DATA: A survey of Scoliosis Research Society members reported rates of neck pain, rotator cuff disease, lateral epicondylitis, and cervical radiculopathy at 3 ×, 5 ×, 10 ×, and 100 × greater than the general population. The use of power-assisted tools in spine surgery to facilitate pedicle cannulation through screw placement during open posterior fixation surgery may reduce torque on the upper limb and risk of overuse injury. METHODS: Pedicle preparation and screw placement was performed from T4-L5 in four cadavers by two board-certified spine surgeons using both manual and power-assisted techniques. EMG recorded muscle activity from the flexor carpi radialis, extensor carpi radialis, biceps, triceps, deltoid, upper trapezius, and neck extensors. Muscle activity was reported as a percentage of the maximum voluntary exertion of each muscle group (%MVE) and muscle exertion was linked to low- (0-20% MVE), moderate- (20%-45% MVE), high- (45%-70% MVE) and highest- (70%-100% MVE) risk of overuse injury based on literature. RESULTS: Use of power-assisted tools for pedicle cannulation through screw placement maintains average muscle exertion at low risk for overuse injury for every muscle group. Conversely with manual technique, the extensor carpi radialis, biceps, upper trapezius and neck extensors operate at levels of exertion that risk overuse injury for 50% to 92% of procedure time. Powerassisted tools reduce average muscle exertion of the biceps, triceps, and deltoid by upwards of 80%. CONCLUSION: Power-assisted technique protects against risk of overuse injury. Elevated muscle exertion of the extensor carpi radialis, biceps, upper trapezius, and neck extensors during manual technique directly correlate with surgeons' self-reported diagnoses of lateral epicondylitis, rotator cuff disease, and cervical myelopathy.Level of Evidence: N/A.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Claeson AA, Schwab FJ, Gandhi AA, et al. Power-assisted Pedicle Screw Technique Protects Against Risk of Surgeon Overuse Injury: A Comparative Electromyography Study of the Neck and Upper Extremity Muscle Groups in a Simulated Surgical Environment. Spine (Phila Pa 1976). 2022. PMID: 33973563. doi:10.1097/BRS.0000000000004097

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。