基于髋部DXA三维建模的体积与几何指标对髋部骨折预测能力优于股骨颈面积骨密度:JPOS队列研究
日本JPOS队列研究纳入1331名40-79岁女性,随访20年,评估基于髋部DXA图像三维建模得到的体积骨密度(vBMD)等指标对髋部骨折的预测能力。结果显示,全髋、股骨颈和转子间区的骨小梁vBMD的AUC显著高于股骨颈面积骨密度(aBMD),但未优于全髋aBMD。
要点
- 基于常规髋部DXA图像的三维建模可获取骨小梁vBMD等指标。
- 骨小梁vBMD对髋部骨折的预测能力显著优于股骨颈aBMD。
- 骨小梁vBMD的预测能力未显著优于全髋aBMD。
核心结论
- 基于常规髋部DXA图像三维建模得到的骨小梁vBMD,对髋部骨折风险的预测能力显著优于股骨颈aBMD,但未优于全髋aBMD。
研究设计与样本
- 日本基于人群的骨质疏松(JPOS)队列研究,纳入1331名基线年龄40-79岁且完成基线及至少一次随访调查的女性,随访20年。
- 基线及10年随访时通过DXA测量髋部aBMD,并用三维建模算法从DXA图像估算体积与几何指标;髋部骨折通过自我报告识别。
主要发现
- 中位随访19.8年期间,共识别68例新发髋部骨折,发生率为2.22/1000人年。
- 全髋骨小梁vBMD的AUC为0.741,股骨颈为0.748,转子间为0.738,均显著大于股骨颈aBMD的AUC(0.701)。
- 全髋、股骨颈和转子间骨小梁vBMD相对于股骨颈aBMD的NRI分别为0.177、0.149和0.195,均有统计学意义。
- 与全髋aBMD相比,骨小梁vBMD的AUC和NRI未见显著改善。
关键数值与推荐
- 预测能力评价指标:受试者工作特征曲线下面积(AUC)和净重分类改善(NRI),以股骨颈aBMD和全髋aBMD为参照。
临床怎么用
- 利用常规髋部DXA图像进行三维建模获取骨小梁vBMD,可能改善髋部骨折风险预测,尤其当仅考虑股骨颈aBMD时。
- 全髋aBMD仍是髋部骨折风险预测的重要参考,骨小梁vBMD未显示优于全髋aBMD。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Areal BMD (aBMD) from DXA is not a sufficiently accurate predictor of fracture. Novel volumetric BMD derived from 3D modeling of the hip from DXA images significantly improved the predictive ability for hip fracture relative to aBMD at the femoral neck, but not aBMD at the total hip. INTRODUCTION: To clarify whether volumetric and geometric indices derived from novel three-dimensional (3D) modeling of the hip using dual-energy X-ray absorptiometric (DXA) images improve hip fracture prediction relative to areal bone mineral density (aBMD). METHODS: We examined 1331 women who had completed the baseline survey and at least one follow-up survey over 20 years (age 40-79 years at baseline). Each survey included aBMD measurement at the hip by DXA. Volumetric and geometric indices of the hip at baseline and the 10-year follow-up were estimated from DXA images using a 3D modeling algorithm. Incident hip fractures during the 20-year follow-up period were identified through self-report. Cox proportional hazards regression models allowing for repeated measurements of predictors and outcomes were constructed, and their predictive ability for hip fracture was evaluated using areas under receiver operating characteristic curves (AUCs) and net reclassification improvement (NRI) over aBMD at the femoral neck (FN) and total hip (TH) as references. RESULTS: During a median follow-up of 19.8 years, 68 incident hip fractures were identified (2.22/1000 person-years). A significantly larger AUC of trabecular volumetric BMD (vBMD) at the total hip (AUC = 0.741), femoral neck (AUC = 0.748), and intertrochanter (AUC = 0.738) and significant NRI (0.177, 0.149, and 0.195, respectively) were observed compared with FN-aBMD (AUC = 0.701), but not TH-aBMD. CONCLUSIONS: vBMD obtained from 3D modeling using routinely obtained hip DXA images significantly improved hip fracture risk prediction over conventional FN-aBMD, but not TH-aBMD. TRIAL REGISTRATION: The Japanese Population-Based Osteoporosis (JPOS) Cohort Study was retrospectively registered as UMIN000032869 in the UMIN Clinical Trials Registry on July 1, 2018.
引用
- Iki M, Winzenrieth R, Tamaki J, et al. Predictive ability of novel volumetric and geometric indices derived from dual-energy X-ray absorptiometric images of the proximal femur for hip fracture compared with conventional areal bone mineral density: the Japanese Population-based Osteoporosis (JPOS) Cohort Study. Osteoporos Int. 2021. PMID: 34041560. doi:10.1007/s00198-021-06013-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。