文献速递运动医学小儿骨科

结合术前MRI与人口学数据预测儿童腘绳肌腱移植物直径

Predicting Autologous Hamstring Graft Diameter in the Pediatric Population Using Preoperative Magnetic Resonance Imaging and Demographic Data.
PubMed 文献 · Am J Sports Med · 2021-04-12

本研究回顾性分析51例18岁以下前交叉韧带重建患儿,利用术前MRI测量半腱肌腱与股薄肌腱多个轴位横截面积并结合人口学数据预测移植物直径。结果显示预测值与术中实际直径在0.5 mm以内一致率为72.5%,1 mm以内为96.1%;加入人口学数据后分别提升至78.4%和98%,对≥8 mm移植物分类敏感度90.4%、特异度88.9%。

要点

  • 术前MRI多点多平面平均横截面积可较准确预测儿童腘绳肌腱移植物直径。
  • 加入人口学数据可进一步提高预测准确性,1 mm以内一致率达98%。
  • 对移植物直径≥8 mm的分类敏感度90.4%、特异度88.9%。

核心结论

  • 取术前MRI多个轴位横截面积的平均值可准确预测儿童ACL重建中自体腘绳肌腱移植物直径,结合人口学数据可协同提高预测准确性。

研究设计与样本

  • 回顾性队列研究(诊断性),证据等级2级,纳入51例18岁以下接受ACL重建的患儿。

主要发现

  • 预测移植物直径与术中实际直径在0.5 mm以内一致者为37/51(72.5%),1 mm以内一致者为49/51(96.1%)。
  • 加入人口学数据后,0.5 mm以内一致率提升至78.4%,1 mm以内提升至98%。
  • 对实际直径≥8 mm者,42例中38例正确分类,敏感度90.4%;对<8 mm者,9例中8例正确分类,特异度88.9%。

关键数值与推荐

  • MRI测量层面为关节线水平、内侧胫骨平台头侧3 cm和头侧5 cm处,取半腱肌腱与股薄肌腱联合横截面积。
  • 移植物类型为四股半腱肌腱或双束半腱肌腱-股薄肌腱联合自体移植物。

临床怎么用

  • 儿童ACL重建术前可利用MRI多层面平均横截面积预测腘绳肌腱移植物直径,辅助选择移植物并降低直径<8 mm相关失败风险。

局限性

  • 原文未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Anterior cruciate ligament (ACL) reconstruction before 18 years of age has been linked with an increased risk for failure when the graft diameter is <8 mm. PURPOSE/HYPOTHESIS: The purpose of this study was to determine whether autologous hamstring graft size can be reliably predicted with the use of preoperative magnetic resonance imaging (MRI) measurements. We hypothesized that the average of multiple axial cross-sectional area MRI measurements for the semitendinosus tendon and gracilis tendon would alone accurately predict graft diameter. Additionally, factoring in specific demographic data to the MRI cross-sectional areas would provide a synergistic effect to the accuracy of graft diameter predictions. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: We retrospectively reviewed 51 pediatric patients undergoing ACL reconstructions (age <18 years) performed using either a quadruple-strand semitendinosus tendon or combined double-bundle semitendinosus tendon-gracilis tendon autograft. Preoperative axial MRI scans at multiple points along the craniocaudal axis-specifically, at the level of the joint line, 3 cm cephalad to the medial tibial plateau, and 5 cm cephalad to the medial tibial plateau-were used to determine the combined cross-sectional area of the semitendinosus and gracilis tendons. The MRI measurements were analyzed using Pearson correlation as well as regression analysis to evaluate strength of correlation between measurements. Binomial linear regression was used to analyze the same predictive variables assessed by multiple regression. RESULTS: The predicted graft diameter was within 0.5 mm of the intraoperative graft size in 37 of 51 (72.5%) patients and within 1 mm of the intraoperative graft size in 49 of 51 (96.1%). With the addition of demographics, the accuracy of predictions increased to 78.4% within 0.5 mm and 98% within 1 mm of the actual graft size. Additionally, 38 of 42 patients whose true graft diameter was ≥8 mm were correctly classified, giving a sensitivity of 90.4%. For those whose true graft diameter was <8 mm, 8 of 9 patients were correctly classified; therefore, the specificity was 88.9%. CONCLUSION: The results of our study suggest that taking the average of multiple preoperative MRI measurements can be used to accurately predict autologous hamstring graft size when approaching pediatric patients undergoing ACL reconstruction.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Partan MJ, Stapleton EJ, Atlas AM, et al. Predicting Autologous Hamstring Graft Diameter in the Pediatric Population Using Preoperative Magnetic Resonance Imaging and Demographic Data. Am J Sports Med. 2021. PMID: 33844606. doi:10.1177/03635465211001771

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。