牛津膝关节评分在翻修膝关节置换术后评估中的效度证据
基于英国国家PROM数据库2013至2019年10,727例翻修膝关节置换术患者的二次数据分析,评估牛津膝关节评分(OKS)的测量性能。9,219例有完整数据,OKS术前均值16.7分,术后6个月29.1分,平均变化+12.5分;内部一致性良好(Cronbach's α 0.88基线,0.94术后),与EQ-5D指数高度相关(r=0.76基线,0.83术后,p<0.001),标准化效应量1.54(95%CI 1.51-1.57),最小重要变化7.5分(95%CI 5.5-8.5),最小重要差异5.2分,最小可检测变化(MDC-90)3.9分,无显著地板或天花板效应。结论认为OKS是翻修膝关节置换术后评估有效且反应良好的工具。
要点
- OKS在翻修膝关节置换术后6个月反应良好,标准化效应量1.54。
- OKS最小重要变化为7.5分,最小重要差异为5.2分,MDC-90为3.9分。
- OKS内部一致性良好,与EQ-5D指数高度相关,无显著地板或天花板效应。
核心结论
- OKS是评估翻修膝关节置换术后结果的有效且反应良好的工具。
研究设计与样本
- 基于英国国家PROM数据库2013至2019年10,727例翻修膝关节置换术患者的二次数据分析,按COSMIN指南评估测量性能。
主要发现
- 9,219例有完整数据,OKS术前均值16.7分(SD 8.1),术后6个月均值29.1分(SD 11.4),平均变化+12.5分(SD 10.7)。
- EQ-5D指数术前中位数0.260(IQR 0.055-0.691),术后中位数0.691(IQR 0.516-0.796),变化中位数+0.240(IQR 0.000-0.567)。
- 内部一致性Cronbach's α基线0.88、术后0.94;OKS总分与EQ-5D指数相关r=0.76(基线)、r=0.83(术后),p<0.001。
- OKS标准化效应量1.54(95%CI 1.51-1.57),EQ-5D指数标准化效应量0.83(95%CI 0.81-0.86)。
关键数值与推荐
- OKS最小重要变化7.5分(95%CI 5.5-8.5),基于最佳截断值,特异度0.72、敏感度0.60、曲线下面积0.66。
- OKS最小重要差异5.2分,MDC-90为3.9分。
- OKS未显示显著地板或天花板效应。
临床怎么用
- 临床可用OKS评估翻修膝关节置换术后患者报告结局,变化≥7.5分可视为最小重要变化。
局限性
- 本研究为二次数据分析,仅纳入英国国家PROM数据集,随访时间为术后6个月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To estimate the measurement properties for the Oxford Knee Score (OKS) in patients undergoing revision knee arthroplasty (responsiveness, minimal detectable change (MDC-90), minimal important change (MIC), minimal important difference (MID), internal consistency, construct validity, and interpretability). METHODS: Secondary data analysis was performed for 10,727 patients undergoing revision knee arthroplasty between 2013 to 2019 using a UK national patient-reported outcome measure (PROM) dataset. Outcome data were collected before revision and at six months postoperatively, using the OKS and EuroQol five-dimension score (EQ-5D). Measurement properties were assessed according to COnsensus-based Standards for the selection of health status Measurement Instruments (COSMIN) guidelines. RESULTS: A total of 9,219 patients had complete outcome data. Mean preoperative OKS was 16.7 points (SD 8.1), mean postoperative OKS 29.1 (SD 11.4), and mean change in OKS + 12.5 (SD 10.7). Median preoperative EQ-5D index was 0.260 (interquartile range (IQR) 0.055 to 0.691), median postoperative EQ-5D index 0.691 (IQR 0.516 to 0.796), and median change in EQ-5D index + 0.240 (IQR 0.000 to 0.567). Internal consistency was good with Cronbach's α 0.88 (baseline) and 0.94 (post-revision). Construct validity found a high correlation of OKS total score with EQ-5D index (r = 0.76 (baseline), r = 0.83 (post-revision), p < 0.001). The OKS was responsive with standardized effect size (SES) 1.54 (95% confidence interval (CI) 1.51 to 1.57), compared to SES 0.83 (0.81 to 0.86) for the EQ-5D index. The MIC for the OKS was 7.5 points (95% CI 5.5 to 8.5) based on the optimal cut-off with specificity 0.72, sensitivity 0.60, and area under the curve 0.66. The MID for the OKS was 5.2 points. The MDC-90 was 3.9 points. The OKS did not demonstrate significant floor or ceiling effects. CONCLUSION: This study found that the OKS was a useful and valid instrument for assessment of outcome following revision knee arthroplasty. The OKS was responsive to change and demonstrated good measurement properties. Cite this article: Bone Joint J 2021;103-B(4):627-634.
引用
- Sabah SA, Alvand A, Beard DJ, et al. Evidence for the validity of a patient-based instrument for assessment of outcome after revision knee arthroplasty. Bone Joint J. 2021. PMID: 33789485. doi:10.1302/0301-620X.103B4.BJJ-2020-1560.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。