文献速递关节外科

小头金属对金属全髋关节置换术后至少20年随访的假瘤研究

Pseudotumors in Small-Head Metal-on-Metal Total Hip Arthroplasties at a Minimum Follow-Up of 20 Years.
PubMed 文献 · J Arthroplasty · 2021-03-10

本研究对1992至1994年间植入小头金属对金属全髋关节假体的患者进行至少20年随访,最终26例(29髋)完成临床评分、血清金属离子检测和MRI检查。结果显示平均Harris髋关节评分88.6,MRI检出21髋假瘤,但有无假瘤患者的血清金属离子水平无显著差异,22.8年累积假体生存率为91.4%。

要点

  • 小头金属对金属全髋长期随访临床功能良好,平均Harris髋关节评分88.6。
  • MRI检出21髋假瘤,但有无假瘤者血清钴铬水平无显著差异。
  • 22.8年累积假体生存率为91.4%,长期随访需关注假瘤。

核心结论

  • 小头金属对金属全髋关节置换术后至少20年随访中,有无假瘤患者的血清金属离子水平无显著差异。

主要发现

  • 平均血清钴水平为1.87 μg/L(±3.44),铬水平为2.23 μg/L(±2.96)。
  • 平均Harris髋关节评分为88.6,临床和功能结果很好。
  • MRI在21髋中检出假瘤,有无假瘤患者在血清金属水平、临床结果评分、人口学数据和髋臼杯倾斜度上无显著差异。
  • 22.8年时累积生存率为91.4%。

临床怎么用

  • 对于小头金属对金属全髋关节置换术后长期随访患者,不能仅依靠血清金属离子水平来筛查假瘤,应结合MRI检查。

局限性

  • 原始98例(105髋)中仅26例(29髋)获得随访,样本量较小且存在失访偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Metal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up. METHODS: At a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained. RESULTS: We found mean serum cobalt levels of 1.87 μg/L (±3.44) and chromium levels of 2.23 μg/L (±2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years. CONCLUSION: This study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors. LEVEL OF EVIDENCE: Therapeutic Level III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kolbitsch P, Noebauer-Huhmann IM, Giurea A, et al. Pseudotumors in Small-Head Metal-on-Metal Total Hip Arthroplasties at a Minimum Follow-Up of 20 Years. J Arthroplasty. 2021. PMID: 33812711. doi:10.1016/j.arth.2021.03.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。