白细胞酯酶与ICM 2018标准诊断假体周围关节感染的比较
该回顾性研究纳入2009年3月至2019年12月单中心接受翻修全髋和全膝关节置换术的患者,术前关节穿刺液行白细胞酯酶(LE)试纸检测,以2018 ICM标准定义假体周围关节感染(PJI)。结果显示LE cutoff≥1+的敏感性0.744、特异性0.906、准确性0.825(95%CI 0.772-0.878),cutoff 2+特异性1.000、敏感性0.513、准确性0.756(95%CI-0.812)。结论认为LE可作为床旁快速廉价检测,建议用LE 1+(阴性或微量)排除感染,2+阈值具有近乎绝对的特异性用于诊断。
要点
- LE cutoff≥1+用于排除PJI:敏感性0.744、特异性0.906、阴性预测值0.891。
- LE cutoff 2+诊断PJI特异性达1.000,但敏感性仅0.513。
- LE是床旁快速廉价检测,其性能依据ICM 2018标准有价值。
核心结论
- LE是床旁快速廉价检测,依据ICM 2018标准其性能有价值。
- 基于本研究队列,建议用LE 1+(结果阴性或微量)作为床旁检测排除感染。
- LE 2+阈值对诊断PJI具有近乎绝对的特异性。
研究设计与样本
- 回顾性研究,纳入2009年3月至2019年12月单中心接受翻修全髋和全膝关节置换术的患者。
- 所有患者切开关节前行关节穿刺,对穿刺液行LE试纸检测。
- PJI采用2018 ICM标准定义。
主要发现
- 按2018 ICM标准,78例诊断为慢性PJI,181例非感染。
- LE cutoff≥1+:敏感性0.744、特异性0.906、阳性预测值0.773、准确性0.825(95%CI 0.772-0.878)、阴性预测值0.891、阳性似然比7.917。
- LE cutoff 2+:敏感性0.513、特异性1.000、准确性0.756(95%CI-0.812)。
关键数值与推荐
- LE cutoff≥1+的敏感性0.744、特异性0.906、阳性预测值0.773、准确性0.825(95%CI 0.772-0.878)、阴性预测值0.891、阳性似然比7.917。
- LE cutoff 2+的敏感性0.513、特异性1.000、准确性0.756(95%CI-0.812)。
- 2018 ICM标准定义PJI,推荐LE以2+为cutoff作为诊断工具。
临床怎么用
- LE试纸可在床旁对关节穿刺液进行快速检测。
- LE 1+(阴性或微量)可作为床旁检测用于排除PJI。
- LE 2+具有近乎绝对特异性,可用于诊断PJI。
局限性
- 本研究为单中心回顾性研究。
- 研究队列为接受翻修全髋和全膝关节置换术的患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A leukocyte esterase (LE) test is inexpensive and provides real-time information about patients suspected of periprosthetic joint infections (PJIs). The 2018 International Consensus Meeting (ICM) recommends it as a diagnostic tool with a 2+ cutoff. There is still a lack of data revealing LE utility versus the ICM 2018 criteria for PJI. METHODS: This is a retrospective study of patients who underwent revision total hip and total knee arthroplasty at a single institution between March 2009 and December 2019. All patients underwent joint aspiration before the arthrotomy, and the LE strip test was performed on aspirated joint fluid. PJI was defined using the 2018 ICM criteria. RESULTS: As per the 2018 ICM criteria, 78 patients were diagnosed with chronic PJI and 181 were not infected. An LE test with a cutoff of ≥1+ had a sensitivity of 0.744, a specificity of 0.906, a positive predictive value of 0.773, an accuracy of 0.825 (95% confidence interval 0.772-0.878), and a negative predictive value of 0.891. The positive likelihood ratio (LR+) was 7.917. Using an LE cutoff of 2 + had a sensitivity of 0.513, a specificity of 1.000, and an accuracy of 0.756 (95% confidence interval-0.812). CONCLUSION: LE is a rapid and inexpensive test which can be performed at the bedside. Its performance is valuable as per ICM criteria. Based on the findings of this study and the given cohort, we suggest using the cutoff of LE1+ (result = negative or trace) as a point of care test to exclude infection, whereas LE at 2 + threshold has near absolute specificity for the diagnosis.
引用
- Chisari E, Yacovelli S, Goswami K, et al. Leukocyte Esterase Versus ICM 2018 Criteria in the Diagnosis of Periprosthetic Joint Infection. J Arthroplasty. 2021. PMID: 33812714. doi:10.1016/j.arth.2021.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。