高屈曲与常规全膝关节置换术十年随访:匹配对照研究
本研究匹配145例高屈曲全膝关节置换术(HF-TKA)与145例常规全膝关节置换术(C-TKA)患者,平均随访121.5个月,比较翻修失败率、活动度、膝关节协会评分及放射透亮线。结果显示HF-TKA翻修率更高,放射透亮线更多,而活动度与评分无差异,提示HF-TKA无优势。
要点
- HF-TKA组件翻修率显著高于C-TKA(P = .001)。
- HF-TKA股骨IV区放射透亮线发生率38.7%,高于C-TKA的13.8%(P < .001)。
- 两组活动度与膝关节协会评分无差异。
核心结论
- HF-TKA在匹配和非匹配分析中均显示更高的翻修失败率。
- HF-TKA放射透亮线发生率更高,但无松动证据。
- HF-TKA在活动度和膝关节协会评分上无优势。
研究设计与样本
- 匹配对照研究,比较同一植入物系统的HF-TKA与C-TKA。
- 2004至2007年间植入,匹配145例HF-TKA与145例C-TKA,平均随访121.5±20.3个月。
- 排除随访不足8年的HF-TKA,12例HF-TKA无法匹配。
主要发现
- 匹配队列中HF-TKA再手术15例(其中组件翻修8例),C-TKA再手术12例(无组件翻修)(P = .001)。
- 非匹配分析显示HF-TKA翻修率更高(HF-TKA: 10/179 vs C-TKA: 27/1347,P = .039)。
- 末次随访HF-TKA股骨IV区放射透亮线38.7%,C-TKA为13.8%(P < .001)。
- 两组活动度和膝关节协会评分无差异。
关键数值与推荐
- 主要结局为需翻修的失败。
- 次要结局包括活动度、膝关节协会评分和放射透亮线。
临床怎么用
- 基于更高翻修率和放射透亮线,HF-TKA相比C-TKA无使用优势。
- 临床选择假体时应考虑HF-TKA的长期失败风险。
局限性
- 部分HF-TKA无法匹配,可能存在选择偏倚。
- 随访时间平均约10年,但未报告更长期结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: High-flexion total knee arthroplasty (HF-TKA) prostheses were designed with hopes of improving knee function. Studies have suggested increased failure with HF-TKAs. The purpose is to compare clinical results of HF-TKA versus conventional TKA (C-TKA) from the same implant system with long-term follow-up. METHODS: This review of prostheses implanted between 2004 and 2007 matched 145 of 179 possible HF-TKAs with 145 of 1347 possible C-TKAs. Mean follow-up was 121.5 ± 20.3 months. We were unable to match 12 HF-TKAs. HF-TKAs with less than 8-year follow-up were excluded. The primary outcome was failure requiring revision. Secondary outcomes included range of motion (ROM), Knee Society Scores (KSS), and radiolucent lines. RESULTS: In the matched cohort, there were 15 HF-TKA reoperations, 8 of which involved component revisions. There were 12 reoperations in the C-TKA cohort but no component revisions (P = .001). The analysis of the unmatched cohorts revealed a higher revision rate for HF-TKAs (P = .039) (HF-TKA: 10/179 vs C-TKA: 27/1347). At final follow-up, HF-TKAs exhibited more prosthesis radiolucent lines without evidence of loosening. Particularly, HF-TKAs demonstrated more femoral zone IV radiolucencies (38.7%) at final follow-up compared with C-TKAs (13.8%) (P < .001). There were no differences found between cohorts in ROM or KSS. CONCLUSION: This study found an increased incidence of failure requiring revision with the HF-TKA in the matched and unmatched analyses. Higher incidences of radiolucent lines were found with HF-TKA. With no observed differences in ROM or KSS and a higher rate of failure with HF-TKA, there appears to be no advantage for use of the HF-TKA.
引用
- Angerame MR, Eschen CL, Johnson RM, et al. Ten-Year Follow-Up of High-Flexion Versus Conventional Total Knee Arthroplasty: A Matched-Control Study. J Arthroplasty. 2021. PMID: 33810919. doi:10.1016/j.arth.2021.03.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。