外侧单髁膝关节置换术植入精度:保留Hoffa脂肪垫内侧入路与经髌外侧入路对比
本研究回顾性纳入2015至2020年175例接受外侧单髁膝关节置换术的患者,其中82例采用外侧入路,93例采用保留Hoffa脂肪垫的内侧入路。结果显示外侧入路在多项影像学精度指标上并未优于内侧入路,内侧入路植入精度良好且两种入路术后PROMs均显著改善。
要点
- 外侧入路胫骨假体与胫骨平台直径比值显著大于内侧入路(23.6% vs 22.2%,P < .001)。
- 外侧入路股骨假体屈曲位置偏差>15°显著更多(P = .002),股骨假体外侧定位率显著更高(P = .007)。
- 两种入路术后PROMs均显著改善,外侧入路在影像学精度上并不优于内侧入路。
核心结论
- 外侧入路在多项影像学精度标准上并不优于保留Hoffa脂肪垫的内侧入路。
- 保留Hoffa脂肪垫的内侧入路植入精度良好,是外侧UKA的良好替代入路。
- 两种入路术后患者报告结局指标均显著改善。
研究设计与样本
- 回顾性研究,纳入2015至2020年175例接受外侧单髁膝关节置换术的患者。
- 82例采用外侧入路,93例采用保留Hoffa脂肪垫的内侧入路。
- 通过术后X线影像学标准评估植入精度,并评估术后PROMs(OKS、LEFS、EQ5D)。
- 统计学显著性设定为P < .05。
主要发现
- 外侧入路胫骨假体与胫骨平台直径比值为23.6%,内侧入路为22.2%,外侧入路显著更大(P < .001)。
- 外侧入路股骨假体屈曲位置偏差>15°显著更多(P = .002)。
- 外侧入路股骨假体斜率偏差数量更多(P = .06)。
- 外侧入路股骨假体外侧定位率显著更高(P = .007)。
- 两种入路术后PROMs均显著改善。
关键数值与推荐
- 胫骨假体与胫骨平台直径比值:外侧入路23.6% vs 内侧入路22.2%(P < .001)。
- 股骨假体屈曲位置偏差>15°:外侧入路显著更多(P = .002)。
- 股骨假体斜率偏差:外侧入路更多(P = .06)。
- 股骨假体外侧定位:外侧入路显著更高(P = .007)。
- 统计学显著性阈值:P < .05。
临床怎么用
- 外侧UKA可考虑采用保留Hoffa脂肪垫的内侧入路,其植入精度良好。
- 选择外侧入路时需注意股骨假体屈曲位置、斜率及外侧定位的偏差风险。
- 两种入路术后PROMs均可显著改善,入路选择可综合精度与软组织保护考量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A small proportion of patients suffer from isolated lateral osteoarthritis where the sole lateral unicompartmental knee arthroplasty (UKA) is a possible treatment option. There, both a medial and a lateral surgical approach can be considered. This study should answer the question whether the lateral approach is superior to a modified medial approach in terms of implantation accuracy and subjective outcome. METHODS: In this retrospective study, 175 patients with lateral UKA were included between 2015 and 2020. In 82 patients, the lateral approach was used, and in 93 patients, the medial approach was used. To assess implantation accuracy, different imaging criteria on postoperative radiographs were analyzed. Postoperative patient-related outcome measurements (PROMs) (OKS, LEFS, and EQ5D) were evaluated. Statistical significance was assumed for P < .05. RESULTS: The tibial implant relation to the tibial plateau diameter in the lateral approach was significantly larger than in the medial approach (23.6% vs 22.2%; P < .001). Significantly more deviations >15° regarding flexion position of the femoral implant (P = .002) and a higher number of deviations of the slope was found (P = .06) in the lateral approach. The lateral approach showed a significantly higher rate of lateral positioning of the femoral component (P = .007). Post-PROMs showed significant improvement in both approaches. CONCLUSION: The lateral approach is not superior regarding different radiological accuracy criteria. The Hoffa´s fat pad-preserving medial approach showed good results in implantation accuracy and therefore is a good alternative to implant lateral UKA. In addition, significant improvement in PROMs could be demonstrated.
引用
- Keppler L, Klingbeil S, Navarre F, et al. Implantation Accuracy of a Lateral Unicompartmental Knee Arthroplasty: A Hoffa´s Fat Pad-Preserving Medial Approach Versus the Transpatellar Lateral Approach. J Arthroplasty. 2021. PMID: 33867207. doi:10.1016/j.arth.2021.03.047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。