文献速递关节外科创伤骨科

压配式桡骨头置换术中的假体柄形状与尺寸是否影响应力遮挡

Does shape and size of the stems affect the stress-shielding around press-fit radial head arthroplasty?
PubMed 文献 · Bone Joint J · 2021-01-01

本研究通过影像学分析52例压配式桡骨头置换术患者,比较圆柱形与圆锥形假体柄对近端桡骨颈吸收(PRNR)的影响。结果显示52例中50例出现PRNR,平均3.9 mm;两组假体柄在B、C水平的髓腔填充率差异显著(p<0.001),但PRNR严重程度与三个柄/髓腔比值均无显著相关性。结论认为PRNR似乎与假体柄形状和尺寸无关。

要点

  • 压配式桡骨头置换术后近端桡骨颈吸收常见,52例中50例出现,平均3.9 mm。
  • 圆柱形与圆锥形假体柄在B、C水平的髓腔填充率差异显著(p<0.001)。
  • PRNR严重程度与假体柄/髓腔比值无显著相关性,组内及组间均如此。

核心结论

  • 压配式桡骨头置换术后的近端桡骨颈吸收似乎与假体柄的形状和尺寸无关。
  • 除假体柄设计外,应研究其他原因以完全解释该现象。

研究设计与样本

  • 回顾性影像学分析,纳入52例压配式桡骨头置换术患者,术后14天及2年时分析X线片。
  • 圆柱形假体柄组22例(组1),圆锥形假体柄组30例(组2)。

主要发现

  • 52例中50例出现近端桡骨颈吸收,平均3.9 mm(范围0至7.4)。
  • 组1在A、B、C水平的髓腔填充率分别为96%、90%、68%,组2分别为96%、72%、57%,B和C水平差异显著(p<0.001)。
  • PRNR严重程度与三个柄/髓腔比值在组内及组间均无显著相关性。

关键数值与推荐

  • 近端桡骨颈吸收在桡骨颈四个象限测量。
  • 髓腔填充率计算为假体柄直径与髓腔直径的比值,测量水平为A(近端)、B(柄中段)、C(柄远端)。

临床怎么用

  • 对于压配式桡骨头置换术后出现近端桡骨颈吸收,不应仅归因于假体柄形状或尺寸。
  • 临床需考虑其他因素解释应力遮挡现象,并进一步研究。

局限性

  • 样本量较小(52例),分组非随机。
  • 仅通过X线片评估,随访2年,可能不足以观察长期变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR. METHODS: The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C). RESULTS: Overall, 50 of the 52 patients displayed PRNR. The mean PRNR observed was 3.9 mm (0 to 7.4). The degree of endomedullary stem filling at levels A, B, and C was 96%, 90%, and 68% in group 1, and 96%, 72%, and 57%, in group 2, with differences being significant at levels B (p < 0.001) and C (p < 0.001). No significant correlations emerged between the severity of PRNR and the three stem/canal ratios either within each group or between the groups. CONCLUSION: PRNR in press-fit RHA appears to be independent of the shape and size of the stems. Other causes besides stem design should be investigated to explain completely this phenomenon. Cite this article: Bone Joint J 2021;103-B(3):530-535.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Giannicola G, Castagna V, Villani C, et al. Does shape and size of the stems affect the stress-shielding around press-fit radial head arthroplasty? Bone Joint J. 2021. PMID: 33641422. doi:10.1302/0301-620X.103B3.BJJ-2020-1421.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。