文献速递关节外科创伤骨科

短柄全髋置换术后股骨近端滋养动脉的影像学评估

Radiographic Evaluation of Proximal Femoral Nutrient Arteries After Total Hip Arthroplasty With a Short Femoral Stem.
PubMed 文献 · J Arthroplasty · 2021-02-10

本研究回顾性分析378髋(332例)接受仅用髓锉压配股骨柄全髋置换的患者,术后6周X线片显示46.3%的髋可见股骨滋养动脉(FNA),均为单皮质,多位于后侧和外侧皮质。性别、年龄、BMI、柄位置和手术入路与FNA存在无相关性。

要点

  • 全髋置换术后约46%的髋X线片可见股骨滋养动脉,易与假体周围骨折混淆。
  • FNA均为单皮质,多位于后侧和外侧皮质,术前X线片已存在。
  • 评估术后X线片时应考虑FNA可能,避免误判为骨折。

核心结论

  • 使用单一仅用髓锉压配股骨柄的全髋置换术后,46%的患者术后X线片可见股骨滋养动脉。
  • 股骨滋养动脉为单皮质,且术前X线片已存在。

研究设计与样本

  • 回顾性队列研究,纳入≥18岁接受初次全髋置换且使用非骨水泥仅用髓锉压配股骨柄、有术后6周随访X线片的患者。
  • 共评估378髋(332例患者),记录人口学特征,评估术后6周正侧位X线片上FNA的存在、位置和形态。

主要发现

  • 术后6周X线片显示46.3%(175髋/378髋)存在FNA。
  • 所有FNA均为单皮质,多数位于后侧和外侧皮质。
  • 性别、年龄、BMI、柄位置和手术入路与FNA的影像学存在无相关性。

关键数值与推荐

  • FNA影像学存在率:46.3%(175髋/378髋)。
  • FNA均为单皮质,多位于后侧和外侧皮质。

临床怎么用

  • 术后评估X线片时,应识别股骨滋养动脉,避免误判为假体周围骨折。
  • 结合术前X线片对比,有助于区分FNA与骨折。

局限性

  • 回顾性研究设计。
  • 仅评估一种仅用髓锉压配股骨柄设计。
  • 仅分析术后6周X线片。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of less invasive approaches and broach only press-fit femoral stems in total hip arthroplasty (THA) may increase the risk for periprosthetic fracture. Proximal femoral nutrient arteries (FNAs) can be mistaken for fractures after THA. Description of FNAs in relation to THA implants is important to better distinguish between FNAs and periprosthetic fractures. The purpose of this study was to evaluate the frequency, location, and morphology of FNAs visible on radiographs after primary THA with a broach-only stem design. METHODS: A retrospective cohort study was performed. Patients ≥18 years who underwent primary THA with a cementless, broach-only stem, and had 6-week follow-up radiographs were included. Patient demographics were recorded. Anteroposterior and lateral radiographs at 6 weeks postoperatively were assessed for the presence of FNA; if present, measurements of vessel location and morphology were obtained. Descriptive statistics were reported. Univariate and multivariate analyses were performed to identify patient characteristics associated with the radiographic presence of perforating vessel. RESULTS: A total of 378 hips were evaluated (332 patients). FNAs were identified radiographically in 46.3% (175 hips/378 hips). All FNAs were found to be unicortical, most observed in the posterior and lateral cortices. Gender, age, BMI, stem position, and surgical approach did not correlate with a presence of FNA on radiograph. CONCLUSION: FNA was seen on postoperative radiographs in 46% of patients after THA with one broach-only stem design. The FNA was unicortical and present on preoperative radiographs. Surgeons should consider this when evaluating postoperative radiographs.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wynn MS, Carender CN, Solsrud E, et al. Radiographic Evaluation of Proximal Femoral Nutrient Arteries After Total Hip Arthroplasty With a Short Femoral Stem. J Arthroplasty. 2021. PMID: 33674162. doi:10.1016/j.arth.2021.02.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。