文献速递关节外科

深度学习工具自动测量全髋关节置换术后髋臼假体倾斜角与前倾角

A Deep Learning Tool for Automated Radiographic Measurement of Acetabular Component Inclination and Version After Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2021-02-16

本研究开发并验证了一种深度学习工具,用于在术后X线片上自动测量全髋关节置换术后髋臼假体的角度位置。研究使用各600张正位骨盆和侧位髋关节X线片训练两个U-Net卷积神经网络模型,测试结果显示模型分割的平均Dice相似系数分别为0.878和0.903,机器与人工测量的倾斜角与前倾角平均差异分别为1.35°和1.39°,差异≥5°的病例不足2.5%。

要点

  • 深度学习工具可自动测量髋臼假体倾斜角和前倾角,平均误差约1.35°和1.39°。
  • 模型在正位和侧位X线片上的分割Dice系数分别为0.878和0.903。
  • 机器与人工测量差异≥5°的病例不足2.5%,精度较高。

核心结论

  • 研究开发了一种高精度的深度学习工具,可自动化测量髋臼假体角度位置,适用于临床和研究场景。

研究设计与样本

  • 使用各600张正位骨盆和侧位髋关节术后X线片开发深度学习模型,手动标注并增强后按8:1:1随机分为训练、验证和测试集,训练两个U-Net卷积神经网络模型各50个epoch。

主要发现

  • 卷积神经网络模型在正位和侧位测试集上的平均Dice相似系数分别为0.878和0.903。
  • 机器与人工测量的倾斜角平均差异为1.35°(σ=1.07°),前倾角平均差异为1.39°(σ=1.27°)。
  • 机器与人工测量差异≥5°的病例不足2.5%。

临床怎么用

  • 该工具可用于临床和研究环境中自动测量全髋关节置换术后髋臼假体的倾斜角和前倾角,减少人工测量的时间和观察者间变异。

局限性

  • 证据等级为III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Inappropriate acetabular component angular position is believed to increase the risk of hip dislocation after total hip arthroplasty. However, manual measurement of these angles is time consuming and prone to interobserver variability. The purpose of this study was to develop a deep learning tool to automate the measurement of acetabular component angles on postoperative radiographs. METHODS: Two cohorts of 600 anteroposterior (AP) pelvis and 600 cross-table lateral hip postoperative radiographs were used to develop deep learning models to segment the acetabular component and the ischial tuberosities. Cohorts were manually annotated, augmented, and randomly split to train-validation-test data sets on an 8:1:1 basis. Two U-Net convolutional neural network models (one for AP and one for cross-table lateral radiographs) were trained for 50 epochs. Image processing was then deployed to measure the acetabular component angles on the predicted masks for anatomical landmarks. Performance of the tool was tested on 80 AP and 80 cross-table lateral radiographs. RESULTS: The convolutional neural network models achieved a mean Dice similarity coefficient of 0.878 and 0.903 on AP and cross-table lateral test data sets, respectively. The mean difference between human-level and machine-level measurements was 1.35° (σ = 1.07°) and 1.39° (σ = 1.27°) for the inclination and anteversion angles, respectively. Differences of 5⁰ or more between human-level and machine-level measurements were observed in less than 2.5% of cases. CONCLUSION: We developed a highly accurate deep learning tool to automate the measurement of angular position of acetabular components for use in both clinical and research settings. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rouzrokh P, Wyles CC, Philbrick KA, et al. A Deep Learning Tool for Automated Radiographic Measurement of Acetabular Component Inclination and Version After Total Hip Arthroplasty. J Arthroplasty. 2021. PMID: 33678445. doi:10.1016/j.arth.2021.02.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。