聚乙烯厚度对内侧活动平台单髁膝关节置换临床结局与生存率的影响
该回顾性研究纳入2305例患者(3030膝)接受内侧活动平台单髁膝关节置换,按聚乙烯厚度分为薄衬垫组(3或4毫米,2640膝)和厚衬垫组(≥5毫米,390膝)。
要点
- 厚聚乙烯衬垫(≥5毫米)增加胫骨无菌性松动翻修风险。
- 两组术后活动度和膝关节协会评分无显著差异。
核心结论
- 内侧活动平台单髁膝关节置换中,较厚的聚乙烯衬垫增加胫骨无菌性松动风险,但不影响全因失败率或临床结局。
研究设计与样本
- 回顾性综述,纳入2004年至2017年接受初次活动平台内侧单髁膝关节置换的患者,最少随访2年或翻修,共2305例患者(3030膝)。
主要发现
- 平均随访5.2年(范围0.5至12.6年),两组术后活动度和膝关节协会评分无显著差异(P > .05)。
- 手法松解率1.3%,两组间无显著差异。
- 薄衬垫组全因翻修率4.02%,厚衬垫组4.58%(P = .6)。
- 厚衬垫组胫骨无菌性松动翻修率1.8%,显著高于薄衬垫组的0.7%(P = .04)。
- 两组在胫骨塌陷或骨折、股骨无菌性松动、关节炎进展、衬垫脱位或其他翻修原因方面无显著差异。
关键数值与推荐
- 薄衬垫组定义为3毫米或4毫米衬垫,共2640膝(87%);厚衬垫组定义为≥5毫米,共390膝(13%)。
临床怎么用
- 在内侧活动平台单髁膝关节置换中,选择较厚聚乙烯衬垫时需权衡胫骨无菌性松动风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The thickness of the polyethylene bearing in medial unicondylar knee arthroplasty (UKA) is determined by the depth of the tibial resection, degree of correctable deformity, and balance of the knee. The purpose of this study is to evaluate whether polyethylene thickness in medial mobile-bearing UKA impacts clinical outcomes and survivorship. METHODS: A retrospective review from 2004 to 2017 identified patients who underwent a primary mobile-bearing medial UKA with 2-year minimum follow-up or revision. A total of 2305 patients (3030 knees) met inclusion criteria. Patients were divided in 2 groups: thin bearing (group 1): 3-mm or 4-mm bearing and thick bearing (group 2): ≥ 5 mm. The thin group consisted of 2640 knees (87%), whereas the thick group had 390 knees (13%). Preoperative and postoperative demographics, range of motion, Knee Society scores, complications, and reoperations were evaluated. RESULTS: Mean follow-up was 5.2 years (range, 0.5 to 12.6). There was no significant difference between groups in postoperative range of motion or Knee Society scores (P > .05). Manipulations were performed in 1.3% of patients and not significantly different between groups. The all-cause revision rate for group 1 was 4.02% and group 2 was 4.58% (P = .6). Revision rates for tibial aseptic loosening were significantly higher in group 2 (1.8%) than those in group 1 (0.7%) (P = .04). There was no significant difference in failure rates between groups for tibial collapse or fracture, femoral aseptic loosening, arthritic progression, bearing dislocation, or other cause of revision. CONCLUSION: This study demonstrated that thicker bearings in medial UKA increased the risk of tibial aseptic loosening, but not all-cause failures or clinical outcomes.
引用
- Crawford DA, Lapsley L, Hurst JM, et al. Impact of Polyethylene Thickness on Clinical Outcomes and Survivorship in Medial Mobile-Bearing Unicondylar Knee Arthroplasty. J Arthroplasty. 2021. PMID: 33741242. doi:10.1016/j.arth.2021.02.062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。