髋关节翻修术中打压植骨:再次翻修时的骨缺损与临床结果
该研究回顾了1992至2016年间45例因无菌性松动接受再次翻修的髋臼翻修病例,这些病例初次翻修时均使用打压植骨(IBG)与骨水泥假体。再次翻修时的Paprosky骨缺损分型较初次翻修时更轻(p=0.020),Harris髋关节评分从术前平均45.4改善至末次随访80.7。9年累计因任何原因再次翻修失败率为9.6%(95%CI 2.9-21.0),无菌性松动为7.5%(95%CI 1.9-18.5)。
要点
- IBG可恢复髋臼骨储备,再次翻修时骨缺损分型较初次翻修更轻。
- 再次翻修使用IBG仍可获得临床改善,但需注意影像学迁移风险。
- 髋关节高度较大与影像学迁移风险升高相关(OR 1.09,95%CI 1.02-1.17;p=0.008)。
核心结论
- IBG可用于髋关节翻修术中的骨储备恢复,在再次翻修中亦有用。
- 更接近髋旋转中心的手术技术可能降低髋臼假体影像学迁移风险。
- 需要更长随访评估固定是否可能恶化。
研究设计与样本
- 回顾性分析382例使用IBG和骨水泥假体的髋臼翻修系列中45髋(45例)因无菌性松动失败的再次翻修病例,时间跨度为1992至2016年。
- 比较初次翻修与再次翻修时的Paprosky髋臼骨缺损分型,并分析临床与影像学结果。
- 采用竞争风险分析进行生存分析。
主要发现
- 初次翻修时骨缺损为19髋Paprosky IIIA型和29髋IIIB型;再次翻修时为7髋II型、27髋IIIA型和11髋IIIB型(p=0.020)。
- 术前平均Harris髋关节评分为45.4(SD 6.4),末次随访时为80.7(SD 12.7)。
- 12髋出现髋臼假体影像学迁移,3髋需进一步翻修手术。
- 9年累计因任何原因再次翻修失败率为9.6%(95%CI 2.9-21.0),因无菌性松动为7.5%(95%CI 1.9-18.5)。
- 髋关节高度较大与影像学迁移风险升高相关(OR 1.09,95%CI 1.02-1.17;p=0.008)。
关键数值与推荐
- Paprosky分型用于评估髋臼骨缺损:初次翻修IIIA型19髋、IIIB型29髋;再次翻修II型7髋、IIIA型27髋、IIIB型11髋(p=0.020)。
- 9年累计因任何原因再次翻修失败率9.6%(95%CI 2.9-21.0),无菌性松动失败率7.5%(95%CI 1.9-18.5)。
- 髋关节高度与影像学迁移的比值比1.09(95%CI 1.02-1.17;p=0.008)。
临床怎么用
- 对于髋臼骨缺损翻修,IBG可恢复骨储备并允许再次翻修时使用。
- 再次翻修使用IBG时,应注意髋关节高度较大者的影像学迁移风险,优化手术技术使其更接近髋旋转中心。
- 术后需长期随访以监测固定是否恶化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Bone stock restoration of acetabular bone defects using impaction bone grafting (IBG) in total hip arthroplasty may facilitate future re-revision in the event of failure of the reconstruction. We hypothesized that the acetabular bone defect during re-revision surgery after IBG was smaller than during the previous revision surgery. The clinical and radiological results of re-revisions with repeated use of IBG were also analyzed. METHODS: In a series of 382 acetabular revisions using IBG and a cemented component, 45 hips (45 patients) that had failed due to aseptic loosening were re-revised between 1992 and 2016. Acetabular bone defects graded according to Paprosky during the first and the re-revision surgery were compared. Clinical and radiological findings were analyzed over time. Survival analysis was performed using a competing risk analysis. RESULTS: Intraoperative bone defect during the initial revision included 19 Paprosky type IIIA and 29 Paprosky type IIIB hips; at re-revision, seven hips were Paprosky type II, 27 type IIIA and 11 were type IIIB (p = 0.020). The mean preoperative Harris Hip Score was 45.4 (SD 6.4), becoming 80.7 (SD 12.7) at the final follow-up. In all, 12 hips showed radiological migration of the acetabular component, and three required further revision surgery. The nine-year cumulative failure incidence (nine patients at risk) of the acetabular component for further revision surgery was 9.6% (95% confidence interval (CI) 2.9 to 21.0) for any cause, and 7.5% (95% CI 1.9 to 18.5) for aseptic loosening. Hips with a greater hip height had a higher risk for radiological migration (odds ratio 1.09, 95% CI 1.02 to 1.17; p = 0.008). CONCLUSION: Bone stock restoration can be obtained using IBG in revision hip surgery. This technique is also useful in re-revision surgery; however, a better surgical technique including a closer distance to hip rotation centre could decrease the risk of radiological migration of the acetabular component. A longer follow-up is required to assess potential fixation deterioration. Cite this article: Bone Joint J 2021;103-B(3):492-499.
引用
- Garcia-Rey E, Saldaña L, Garcia-Cimbrelo E, et al. Impaction bone grafting in hip re-revision surgery. Bone Joint J. 2021. PMID: 33641418. doi:10.1302/0301-620X.103B3.BJJ-2020-1228.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。