文献速递脊柱外科小儿骨科

凸侧椎弓根螺钉低植入密度技术矫正青少年特发性脊柱侧凸

Correction of adolescent idiopathic scoliosis using a convex pedicle screw technique with low implant density.
PubMed 文献 · Bone Joint J · 2021-01-01

该回顾性研究比较凸侧椎弓根螺钉低植入密度技术(顶椎周围凹侧置钉)与双侧椎弓根螺钉高植入密度技术矫正胸段青少年特发性脊柱侧凸的疗效。结果显示低密度组植入物数量和密度显著更低、手术时间更短,而术后Cobb角、椎体旋转、相对矫正率及患者报告结局均无统计学差异。

要点

  • 凸侧低密度技术植入物数量14.5 vs 17.1、密度1.5 vs 1.9,均显著更低(p<0.001)。
  • 低密度组手术时间平均缩短27分钟,每固定椎体手术时间减少19%(p=0.011)。
  • 两组术后Cobb角、椎体旋转、相对矫正率及PROMs无统计学差异。

核心结论

  • 凸侧低植入密度技术矫正胸段青少年特发性脊柱侧凸的Cobb角与椎体旋转效果与高密度双侧置钉技术相似。
  • 顶椎周围凹侧置钉及凹侧 primary 矫正似乎并非获得良好手术结果的必要条件。
  • 低植入密度组手术时间更短,该技术有潜力减少并发症和成本。

研究设计与样本

  • 回顾性研究,纳入51例胸段青少年特发性脊柱侧凸患者。
  • 凸侧椎弓根螺钉组(Group 2)26例,顶椎周围置钉;对照组(Group 1)25例,双侧椎弓根螺钉。
  • 回顾病历并评估术前、术后X线片,记录术后患者报告结局指标(PROMs)。

主要发现

  • Group 2植入物数量为14.5,Group 1为17.1,差异显著(p<0.001)。
  • Group 2植入物密度为1.5,Group 1为1.9,差异显著(p<0.001)。
  • Group 2手术时间较Group 1缩短27分钟,平均217分钟(SD 50.5;120至346)。
  • Group 2每固定椎体手术时间减少19%(p=0.011)。
  • 两组术后Cobb角、椎体旋转、相对矫正率及术后PROMs均无统计学差异。

临床怎么用

  • 在胸段青少年特发性脊柱侧凸手术中,可考虑采用凸侧低植入密度技术以减少植入物使用和缩短手术时间。
  • 顶椎周围凹侧置钉并非获得良好矫正效果的必要条件。

局限性

  • 本研究为回顾性研究。
  • 样本量较小(共51例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. METHODS: We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients' charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. RESULTS: The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. CONCLUSION: Despite a lower implant density and achieving correction through a convex rod, surgical correction of the Cobb angle and vertebral body rotation was similar in both groups. Periapical pedicle screws and primary correction on the concave side do not seem to be mandatory in order to achieve good surgical results in idiopathic thoracic scoliosis. The operating time was shorter in the group with lower implant density. In conclusion, the technique provided good results and has the potential to reduce complications and costs. Cite this article: Bone Joint J 2021;103-B(3):536-541.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Ferlic PW, Hauser L, Götzen M, et al. Correction of adolescent idiopathic scoliosis using a convex pedicle screw technique with low implant density. Bone Joint J. 2021. PMID: 33641409. doi:10.1302/0301-620X.103B3.BJJ-2020-0760.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。