等弹性单杯与模块化压配杯在全髋关节置换术后保留更多髋臼与股骨骨量的前瞻性随机对照试验
两组整体髋臼周围骨密度平均下降15.1%和16.5%,无显著差异;但RM组极区骨密度下降4.9%±10.0%,显著低于IT组的15.9%±14.9%(p=0.005)。
要点
- 两组术后4年髋臼周围整体骨密度均显著下降,组间无显著差异。
- 等弹性单杯在髋臼极区的骨密度丢失显著少于模块化钛杯。
- 需更长随访才能判断两种杯系统的长期骨密度变化趋势。
核心结论
- 两种杯系统术后4年髋臼周围整体骨密度均出现相关丢失,组间无显著差异。
- 等弹性单杯在髋臼极区的术后骨丢失显著少于模块化钛杯。
研究设计与样本
- 采用双能X线吸收法在术后1周(基线)和4年测定髋臼周围骨密度,并分为4个感兴趣区,主要结局为髋臼周围骨密度下降。
主要发现
- 术后4年髋臼周围骨密度平均下降:RM组15.1%,IT组16.5%。
- 髋臼周围结构整体比较,两组间无显著差异。
- 极区骨密度下降:RM组4.9%±10.0%,IT组15.9%±14.9%,p=0.005,组间差异显著。
临床怎么用
- 对于需保留髋臼周围骨量的全髋关节置换患者,等弹性单杯可能在极区减少骨丢失。
- 术后4年两组整体骨密度下降程度相近,选择杯系统时需结合极区骨保留需求综合判断。
局限性
- 需更长随访才能对两种杯系统的长期骨密度变化得出结论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: For cup revision after total hip arthroplasty, sufficiently good periacetabular bone stock is a prerequisite for fixation of the revision implant. Cementless cups can lead to a relevant reduction of peri-implant bone mineral density (BMD) through stress-shielding. METHODS: Fifty patients were included in this prospective randomized controlled trial. Group 1 (RM group) received an isoelastic monoblock cup (RM Pressfit vitamys; Mathys). Group 2 (IT group) received a modular titanium cup (Allofit-S IT Alloclassic with a polyethylene liner; Zimmer). Periacetabular BMD was determined and subdivided into 4 regions of interest by dual x-ray absorptiometry at 1 week (baseline) and at 4 years postoperatively. Our primary outcome was reduction in periacetabular BMD. RESULTS: Periacetabular BMD was reduced by an average of 15.1% in the RM group and 16.5% in the IT group at 4 years postoperatively. No significant difference was found between the 2 groups over the periacetabular structure as a whole. However, the decrease of BMD in the polar region was significantly different in the RM group (4.9% ± 10.0%) compared with the IT group (15.9% ± 14.9%, p = 0.005). Use of the isoelastic RM cup showed significantly less bone loss than the modular IT cup. CONCLUSIONS: Relevant loss of BMD at 4 years after surgery was identified in the periacetabular region in both groups. No differences between the 2 cup systems were found when looking at the overall periacetabular region. As a secondary outcome, less postoperative periacetabular bone loss occurred in the polar region when an isoelastic cup was used. Longer follow-up is required to allow for conclusions to be drawn about the long-term course of the 2 cup systems. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
引用
- Brodt S, Jacob B, Nowack D, et al. An Isoelastic Monoblock Cup Retains More Acetabular and Femoral Bone Than a Modular Press-Fit Cup: A Prospective Randomized Controlled Trial. J Bone Joint Surg Am. 2021. PMID: 33617161. doi:10.2106/JBJS.19.00787