髋臼锉过大对带领缎面复合梁骨水泥柄全髋关节置换临床与影像学结果的影响
本研究比较两种不同过大髋臼锉在复合梁骨水泥柄(DCM-J)全髋关节置换中的临床与影像学结果。105髋连续病例中,最小随访10年的患者里,38髋使用1.5mm过大锉(S组),36髋使用0.5mm过大锉(M组)。两组JOA髋评分均显著改善且假体生存率100%(排除感染性松动),但M组应力遮挡发生率显著高于S组,提示应为骨水泥柄准备足够的骨水泥套空间。
要点
- 两组JOA髋评分均显著改善,假体生存率100%(排除感染性松动)。
- M组应力遮挡在2年、5年及≥10年随访时均显著高于S组。
- 皮质肥厚随时间出现,但末次随访时两组患病率无显著差异。
核心结论
- DCM-J柄在两组均取得良好临床结果。
- 使用0.5mm过大锉的全髋关节置换应力遮挡发生率显著高于1.5mm过大锉,提示应为骨水泥柄准备足够的骨水泥套空间。
研究设计与样本
- 连续系列105髋在2006至2010年间接受使用DCM-J柄的混合型全髋关节置换。
- 在最小随访10年的患者中,38髋使用1.5mm过大锉(S组),36髋使用0.5mm过大锉(M组)。
- 评估日本骨科协会髋评分及影像学表现,包括骨水泥套厚度、应力遮挡和皮质肥厚。
主要发现
- 两组JOA髋评分术后均显著改善,排除感染性松动后假体生存率均为100%。
- 术后即刻影像学评估显示,M组在Gruen 1区骨水泥套厚度显著大于S组,而2-7区两组无差异。
- 应力遮挡在M组显著多于S组:术后2年(P = .011)、5年(P = .012)及≥10年(P = .038)。
- 皮质肥厚随时间出现,但末次随访(平均11.7年,范围10-14年)时两组患病率无显著差异。
临床怎么用
- 使用复合梁骨水泥柄行全髋关节置换时,应为骨水泥柄准备足够的骨水泥套空间。
- 避免使用过小过大锉(如0.5mm)以减少应力遮挡风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study aimed to compare the clinical and radiographic outcomes of using two different oversized rasps in total hip arthroplasty (THA) with a composite beam cemented stem (DCM-J). METHODS: A consecutive series of 105 hips underwent hybrid THA using the DCM-J stem between 2006 and 2010. Among the patients with a minimum 10-year follow-up, a 1.5-mm oversized rasp was used in 38 hips (group S), whereas a 0.5-mm oversized rasp was used in 36 hips (group M). The Japanese Orthopedic Association hip score and radiographic findings were evaluated, including cement mantle thickness, stress shielding, and cortical hypertrophy. RESULTS: The Japanese Orthopedic Association hip score was significantly improved postoperatively with 100% of the implant survival rate in both groups when septic loosening was excluded. Radiographic assessment performed immediately postoperatively revealed that the cement mantle thickness was significantly larger in group M than group S in Gruen zone 1 but did not differ between groups in zones 2-7. Stress shielding was significantly more frequent in group M than group S at 2 years (P = .011), 5 years (P = .012), and ≥10 years postoperatively (P = .038). Cortical hypertrophy appeared in a time-dependent manner; however, the prevalence did not significantly differ between groups at final follow-up at a mean of 11.7 years (range 10-14 years) postoperatively. CONCLUSIONS: The DCM-J stem achieved good clinical results in both groups. Stress shielding was significantly more frequent in THA using the 0.5-mm rasp than the 1.5-mm rasp, indicating that sufficient cement mantle room should be prepared for the cemented stem.