文献速递关节外科

大股骨头配小髋臼杯联合高交联聚乙烯在全髋关节置换术中是否安全

The Lawrence D. Dorr Surgical Techniques & Technologies Award: Using Big Heads and Small Acetabular Components With Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: Is It Safe?
PubMed 文献 · J Arthroplasty · 2021-01-30

该回顾性研究纳入2000至2017年882例使用36 mm股骨头、髋臼杯≤52 mm且高交联聚乙烯内衬的初次全髋关节置换术,平均年龄66岁、88%为女性、平均BMI 30 kg/m²。整个队列无内衬骨折或脱位,10年脱位、任何翻修和任何再手术的累积发生率分别为3.2%、5.6%和9.3%,平均线性股骨头穿透0.042 mm/y、体积磨损率44 mm³/y。

要点

  • 36 mm股骨头配≤52 mm髋臼杯和高交联聚乙烯内衬未出现内衬骨折或脱位。
  • 10年脱位、任何翻修、任何再手术累积发生率分别为3.2%、5.6%、9.3%。
  • 平均线性股骨头穿透0.042 mm/y,平均体积磨损率44 mm³/y。

核心结论

  • 在大样本初次全髋关节置换术中,大股骨头配小髋臼杯未发现内衬骨折或脱位,中期脱位、翻修和再手术累积发生率低。

研究设计与样本

  • 回顾性识别2000至2017年882例初次全髋关节置换术,使用36 mm股骨头、髋臼杯≤52 mm和高交联聚乙烯内衬。
  • 平均年龄66岁,88%为女性,平均体重指数30 kg/m²,平均随访4年。
  • 采用竞争风险模型评估脱位、任何翻修和任何再手术的累积发生率。
  • 至少10年随访时(n=18)用验证过的影像学技术评估骨溶解和股骨头穿透。
  • 证据等级为IV级。

主要发现

  • 整个队列无内衬骨折或脱位。
  • 10年脱位累积发生率为3.2%,任何翻修为5.6%,任何再手术为9.3%。
  • 平均线性股骨头穿透为0.042 mm/y,平均体积磨损率为44 mm³/y。
  • 长期随访中无全髋关节置换术显示骨溶解或组件松动证据。

关键数值与推荐

  • 使用36 mm股骨头和髋臼杯≤52 mm配高交联聚乙烯内衬的初次全髋关节置换术。
  • 10年脱位累积发生率3.2%,任何翻修5.6%,任何再手术9.3%。
  • 平均线性股骨头穿透0.042 mm/y,平均体积磨损率44 mm³/y。

临床怎么用

  • 在合适患者中,36 mm股骨头配≤52 mm髋臼杯和高交联聚乙烯内衬未增加内衬骨折或脱位风险。
  • 中期脱位、翻修和再手术发生率低,磨损率低且无骨溶解证据。

局限性

  • 为回顾性研究,证据等级IV级。
  • 平均随访4年,仅18例完成至少10年影像学评估。
  • 88%为女性,平均体重指数30 kg/m²,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Contemporary total hip arthroplasty (THA) employs larger femoral heads to optimize hip stability. However, the combination of large femoral heads and comparatively small acetabular components poses a potential risk for implant failure secondary to polyethylene (PE) liner fracture or dissociation. The purpose of this study was to evaluate the incidence of liner fracture or dissociation, implant survivorship, and PE wear rates in primary THAs using large femoral heads and small acetabular components. METHODS: Between 2000 and 2017, we retrospectively identified 882 primary THAs with 36 mm femoral heads and acetabular components ≤52 mm with highly cross-linked polyethylene liners. Mean age was 66 years, 88% were females, and mean body mass index was 30 kg/m2. We evaluated the cumulative incidences of dislocation, any revision, and any reoperation utilizing a competing risk model. Osteolysis and femoral head penetration were assessed with a validated radiographic technique at minimum 10-year follow-up (n = 18). Mean follow-up was 4 years. RESULTS: There were no liner fractures or dissociations in the entire cohort. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.2%, 5.6%, and 9.3%, respectively. Mean linear femoral head penetration was 0.042 mm/y and mean volumetric wear rate was 44 mm3/y. No THAs demonstrated evidence of osteolysis or component loosening at long-term follow-up. CONCLUSION: In a large cohort of primary THAs pairing large femoral heads with small acetabular components, there was no evidence of liner fracture or dissociation. Cumulative incidences of dislocation, any revision, and any reoperation were low at mid-term. LEVEL OF EVIDENCE: IV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Baker CE, Bukowski BR, Abdel MP, et al. The Lawrence D. Dorr Surgical Techniques & Technologies Award: Using Big Heads and Small Acetabular Components With Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: Is It Safe? J Arthroplasty. 2021. PMID: 33622530. doi:10.1016/j.arth.2021.01.067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。