股骨颈自体骨移植联合骨水泥髋臼假体重建Crowe III型脱位髋
本研究评估了22例Crowe III型脱位髋患者(28髋)采用股骨颈自体骨移植联合骨水泥髋臼假体行髋臼解剖重建的长期疗效,18例(21髋)随访平均27.2年,所有骨移植均愈合无塌陷,仅3例髋臼假体松动,25年假体生存率86.4%。
要点
- 股骨颈自体骨移植联合骨水泥髋臼假体在真臼水平重建,长期结果良好。
- 所有骨移植均愈合无塌陷,仅3例髋臼假体发生松动。
- 以机械松动或翻修为终点的25年假体生存率为86.4%。
核心结论
- 采用股骨颈自体骨移植并将骨水泥髋臼假体置于真臼,可为Crowe III型脱位髋患者提供良好的长期结局。
研究设计与样本
- 回顾性研究纳入1979至2000年间22例Crowe III型脱位髋患者共28髋,均行股骨颈自体骨移植联合Charnley骨水泥髋臼假体全髋关节置换术。
- 所有患者均为女性,手术时平均年龄54岁(范围35至68岁)。
- 18例患者(21髋)完成随访,平均随访27.2年(范围20至33年)。
主要发现
- 术后即刻X线显示髋臼假体中心至泪滴线平均垂直距离21.5 mm(SD 3.3;范围14.5至30.7)。
- 骨移植对髋臼假体的平均覆盖率为46%(SD 6%;范围32%至60%)。
- 所有骨移植均愈合无塌陷,仅3例髋臼假体发生松动。
- 以机械松动或翻修为终点的髋臼假体25年生存率为86.4%。
临床怎么用
- 对于Crowe III型脱位髋伴髋臼骨缺损患者,可考虑采用股骨颈自体骨移植联合骨水泥髋臼假体在真臼水平行解剖重建。
局限性
- 样本量较小(22例患者28髋),且仅18例(21髋)完成长期随访。
- 研究为回顾性设计,所有患者均为女性,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. METHODS: A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation. RESULTS: Radiographs immediately after surgery showed a mean vertical distance from the centre of the hip to the teardrop line of 21.5 mm (SD 3.3; 14.5 to 30.7) and a mean cover of the acetabular component by bone graft of 46% (SD 6%; 32% to 60%). All bone grafts united without collapse, and only three acetabular components loosened. The rate of survival of the acetabular component with mechanical loosening or revision as the endpoint was 86.4% at 25 years after surgery. CONCLUSION: The technique of using autologous bone graft from the femoral neck and placing a cemented acetabular component in the true acetabulum can provide good long-term outcomes in patients with Crowe type III dislocated hips. Cite this article: Bone Joint J 2021;103-B(2):299-304.
引用
- Goto E, Umeda H, Otsubo M, et al. Cemented acetabular component with femoral neck autograft for acetabular reconstruction in Crowe type III dislocated hips. Bone Joint J. 2021. PMID: 33517728. doi:10.1302/0301-620X.103B2.BJJ-2020-1214.R1