胫骨与股骨假体冠状位对线对单髁膝关节置换临床结果与生存率的影响
本研究基于单中心264例固定平台骨水泥型内侧单髁膝关节置换的前瞻性登记数据,分析术后影像学测量的胫骨假体冠状角(TCCA)与股骨假体冠状角(FCCA)对临床评分及假体生存的影响。发现TCCA与FCCA存在显著双向交互作用,TCCA 2°–4°且FCCA 0°–2°与十年最佳患者报告结局及十五年更优生存率相关。
要点
- TCCA与FCCA存在显著双向交互作用,应联合评估两者对线。
- TCCA 2°–4°且FCCA 0°–2°与十年最佳膝关节评分及满意度相关。
- 该最佳对线组合组十五年生存率100%,非最佳组为92%(95%CI 88%–96%)。
核心结论
- TCCA与FCCA存在显著双向交互作用,未来研究应同时评估两者对线。
- TCCA 2°–4°且FCCA 0°–2°的患者十年患者报告结局最佳且十五年生存率更优。
研究设计与样本
- 分析单中心前瞻性登记数据,共264例固定平台骨水泥型内侧单髁膝关节置换。
- 术后X线片测量TCCA与FCCA并分析绝对值,平均随访14年(12–16年)。
主要发现
- TCCA与FCCA存在显著双向交互作用。
- 校正交互作用后,TCCA 2°–4°且FCCA 0°–2°与十年膝关节评分改善及满足期望和满意度概率最高相关。
- 最佳组十五年生存率100%,非最佳组92%(95%CI 88%–96%),差异显著。
关键数值与推荐
- 最佳对线组合:TCCA 2°–4°且FCCA 0°–2°。
- 最佳组十五年生存率100%,非最佳组92%(95%CI 88%–96%)。
- 临床评估采用KSKS、KSFS、OKS、SF-36及ROM,并记录期望满足与满意度。
临床怎么用
- 术中应同时关注胫骨与股骨假体冠状位对线,而非单独评估任一角度。
- 可参考将TCCA控制在2°–4°、FCCA控制在0°–2°以优化十年结局与十五年生存。
局限性
- 单中心登记数据,样本量264例,结论外推需谨慎。
- 仅分析冠状位对线,未涉及矢状位等其他因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA. METHODS: Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups. RESULTS: Significant two-way interaction effects between TCCA and FCCA were identified. Adjusted for each other and their interaction, a TCCA of between 2° and 4° and a FCCA of between 0° and 2° were found to be associated with the greatest improvements in knee scores and the probability of fulfilling expectations and satisfaction at ten years. Patients in the optimal group whose TCCA and FCCA were between 2° and 4°, and 0° and 2°, respectively, had a significant survival benefit at 15 years compared with the non-optimal group (optimal: survival = 100% vs non-optimal: survival = 92%, 95% confidence interval (CI) 88% to 96%). CONCLUSION: Significant two-way interactions between the TCCA and FCCA demonstrate the importance of evaluating the alignment of the components concomitantly in future studies. By doing so, we found that patients who concomitantly had both a TCCA of between 2° and 4° and a FCCA of between 0° and 2° had the best patient-reported outcome measures at ten years and better survivorship at 15 years. Cite this article: Bone Joint J 2021;103-B(2):338-346.
引用
- Khow YZ, Liow MHL, Lee M, et al. The effect of tibial and femoral component coronal alignment on clinical outcomes and survivorship in unicompartmental knee arthroplasty. Bone Joint J. 2021. PMID: 33517724. doi:10.1302/0301-620X.103B2.BJJ-2020-0959.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。